CFN Series System
3-4
03/07/03
✍
5. BREAKER NUMBERS
Indicate the breaker number for each of the following. All breakers pertaining to the system
should be in the OFF position.
Power conditioner:
AC Surge Protector: (Profit Point)
Islander: (If master unit is not on power conditioner)
PCUs: (pump control units)
ICRs: (island card readers)
Hose/Brkr #: (hose outlets 1 to 32)
Answer the following questions:
What components are on power conditioner? Fill in all that apply.
What components are on AC Surge Protector?
Fill in all that apply.
Are all GASBOY components on same breaker?
Answer Y or N.
NOTE: The power conditioner must be on its own separate breaker. The Site Controller II, data
terminal, modem, standalone receipt printer, and console should be connected to the
output of the power conditioner.
The AC Surge Protector Strip should be on the same breaker as the power conditioner;
however, if this is not possible, it must be the same phase of power as the power
conditioner breaker. The Profit Point, receipt printer, and RS-485 to RS-232 convertor
must be plugged into the same AC Surge Protector Strip. If the scanner requires external
power, it must be plugged into the same AC Surge Protector Strip.
✍
6. SYSTEM ENVIRONMENT
Describe the location and environment of each system component (e.g., office, outside, air
conditioned, heated) Make sure the Site Controller II is well-ventilated. Nothing should rest on
the top of the Site Controller or around its vents.