beautypg.com

Gasboy CFN Series SCII Start-Up Manual User Manual

Page 107

background image

Customer Training

03/07/03

13-3

g. Valid types are 4 and 5. Type a number 4 or 5 and press RETURN or just press

RETURN if you are using version 1.0 or above. The Site Controller prompts you to
Verify.

h. Type Y and press RETURN. You will hear the drive activate. Wait 20 to 30 seconds.

i.

Press CTRL and C together. This deactivates the drive and completes the cleaning
process.

j.

After the disk drive access light goes off, remove the diskette and check off a box on the
usage label. After the recommended number of uses, or if the diskette becomes
discolored, discard the diskette.

For systems with Fuel Point, demonstrate the following:

Using the Programmer to program, read, and calibrate a VM

Using the Master Authorizer to authorize a sale

Using the VM to authorize a sale

How to suspend and resume Fuel Point transactions

For systems using the Key option, inform users of the following:

To prevent key read errors, perform the following maintenance on the keys as needed.
Clean the key’s contacts using isopropyl alcohol and a toothbrush. Dip the toothbrush in
the alcohol and brush the contacts of the key until they are clean.