Jumpers & Switch Settings

03/07/03

5-11

An S3 switch enables the diagnostic mode of the ICR. Diagnostic mode is enabled when the
switch is in the down position.

Diagnostic tests can be started by keeping the face of
the ICR open and pressing the START OVER key on
the keypad.

NOTE:

If you have the island receipt printer, see the Star Receipt Printer Maintenance
Manual, C08951, for switch settings and other information.

ICR CPU PCB Jumper Settings

Jumpers on the CPU PCB are used for very basic configurations on the PCB and usually do not
need to be set in the field.

Reader Type

Disable Pumps PC Board Jumper Settings

The Disable Pumps Stop PC Board is located within the head of the Island Card Reader. It is on
the left side directly below the board labeled RS-485 Protection Board. If the site's island card
reader is equipped with a Disable Pumps button, check the K1 jumper on the Disable Pumps PC
Board. The Disable Pumps button shuts off pumps regardless of the jumper setting, but the
setting determines the following:

If the jumper is on and the site is configured for disable pumps, when the Disable Pumps
button is pressed, the pumps are shut down and the site logs an Emergency Stop condition.

If the jumper is off and Disable Pumps is pressed, the pumps just shut off and no message is
logged at the Site Controller.

ISLANDER

Card Reader

For the card reader switch settings, refer to the island card reader settings earlier in the section.
When viewing the head of the Islander from the rear, the card reader CPU board is located on the
inside of the left partition closest to the front of the head.