Data terminal, Modem – Gasboy CFN Series SCII Start-Up Manual User Manual
Page 85

Communication Tests
03/07/03
10-3
DATA TERMINAL
1.
Be sure both the data terminal and printer are ON.
2.
Locate the SELECT button on the printer and make sure it lights.
3.
Press RETURN. (You may have to set up switches and parameters on the terminal). The
system should respond: sign on.
4.
Type GASBOY and press RETURN.
NOTE: For security reasons, GASBOY will not print as you type it.
The system should respond: Connected to site 1001 on along with the day, date, and time,
followed by the command prompt (A
*
or C
*
). For an Islander, the command prompt is E
*
.
5.
Type P DA and press RETURN. The system prints the date, time, transaction numbers,
sequence number, and version number, followed by the command prompt (A
*
, C
*
, E
*
).
6.
Type LOG MESS...Testing Okidata Printer
The printer should repeat the typed message plus the date and time.
7.
Type EX and press RETURN. The system prints Sign off, along with the day, date, and
time. When connected to the port 0, the system goes into the monitor mode.
MODEM
If modem is not supplied by GASBOY, it must be set up using the following parameters:
-
modem hangs up with on/off transmission of DTR
-
auto answer enabled
-
carrier detect present when connection is complete
-
jack select RJ41S RJ455
-
bell compatible with 103/212A modems
-
line error detect disabled
-
result code disabled
NOTE:
This procedure verifies remote polling only. This is not a network test. Consult your
network representative for network testing.
1.
Turn on the site modem and the modem/data terminal device from which the call will
originate.
2.
Set communication program to proper baud rate (2400 default), N, 8, 1 (see the operator's
manual that comes with the modem).
3.
Dial up the CFN site and establish a communication link with the system.
4.
Press RETURN. The system should respond Sign on.
5.
Type GASBOY and press RETURN
NOTE: For security reasons, GASBOY will not print as you type it.
The system should respond: Connected to site 1001 on along with the day, date, and time,
followed by the command prompt (A
*
or C
*
). For an Islander, the command prompt is E
*
.
6.
Type P DA and press RETURN. The system prints the date, time, transaction numbers,
sequence number, and version number, followed by the command prompt (A
*
, C
*
, or E
*
).
7.
Type EX and press RETURN. The system prints Sign off when connected to the remote
port, and terminates the communication line.