2. SYSTEM IDENTIFICATION

Site #:

Number of the site.

Checkmark the components that this site has:

Indicate the serial number, program version number for each of the following:

SC II/Islander II:

SC II/Islander II unit. Also indicate the program name and debug
version. (e.g., 12345 2.0 BUYPASS DSITE V3.2C).

PCU (s):

Serial number of pump control unit; program version from PCU
CPU PCB.
If pedestal pump control unit; program version from PCU CPU
PCB.

ICR (s):

Island Card Readers, program version from Reader CPU PCB.
Also indicate Y or N if the island card reader has a receipt printer,
has pedestal PCU or is set up as a car wash or gate controller.

Console:
Profit Point:
Current Loop Driver:
Standalone Receipt Printer:
PIN Pad:

PC SOFTWARE

If applicable, indicate the version number of the PC software
assigned to this site.

PC Make and Model:

Indicate the make and model of the PC being used at this site.

DOS Version:

Indicate the DOS version that is running on the customer's PC.

NOTE: The serial number for each system device can be found on the ID tag located on the

outside cover of that device. Islander refers to the master unit (with the site controller
built-in). Use ICR 1 to define the master unit. Define all other readers starting with ICR 2.

3. SYSTEM DESCRIPTION

PUMP #

Indicates the pump number.

HOSE #

Indicates hose outlet number.

FUEL TYPE:

The type of fuel dispensed by that pump or dispenser (e.g., No-
Lead, Regular, etc.).

FUEL CODE:

The product code number (1-2 digits) assigned to that fuel type.

PUMP MAKE:

The name of the manufacturer of the pump or dispenser.

MODEL #:

The model number of the pump or dispenser.

SERIAL #:

The serial number of the pump or dispenser.

CONTINUED