3.6

Operation

3

Safety Mat/Safe Edge

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

3-8

3.6

Operation

3600

Operation

3-

_Dummy-Vorlage

The safety system can only be started if the pressure-sensitive protec-

tive device has not been activated. The unit detects the operating mode

set on start-up.

3.6.1

Diagnostic word

Diagnostic word

3-

Schaltmatte-Diagnosewort

Messages can be queried in the PNOZmulti Configurator in bit mode

and linked further within the program.

Bit 0: Pressure-sensitive protective device clear, enable issued

Bit 2: Pressure-sensitive protective device activated

Bit 3: Waiting for reset

Bit 4: Waiting for start-up test

Bit 6: Open circuit detected, signal error