4 cross muting, 1 position of the muting sensors, 2muting – Pilz PNOZ m1p base unit User Manual
Page 24: 4 operating modes
2.4
Operating modes
2
Muting
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
2-16
2.4.4
Cross muting
Cross muting
2-
2.4.4.1
Position of the muting sensors
Position of the muting sensors
2-
Muting_Betriebsarten_Kreuz- Muting-Anordnung der Muting-Sensoren
Muting sensors may be reflective or send/receive light beam devices,
for example. The beams must always intersect within the danger
zone.
The muting sensors must be positioned in such a way that the light
curtain is interrupted before the beam intersection can be reached
from outside the danger zone.
Muting sensors MS3 and MS4 are not used.
WARNING!
Loss of safety function due to incorrect position of muting
sensors
Depending on the application, serious injury or death may result.
Ensure that you comply with the installation dimensions shown
in the figure overleaf.
AOPD
AOPD
MS1
MS2