2.4

Operating modes

2

Muting

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

2-16

2.4.4

Cross muting

Cross muting

2-

2.4.4.1

Position of the muting sensors

Position of the muting sensors

2-

Muting_Betriebsarten_Kreuz- Muting-Anordnung der Muting-Sensoren

Muting sensors may be reflective or send/receive light beam devices,

for example. The beams must always intersect within the danger

zone.

The muting sensors must be positioned in such a way that the light

curtain is interrupted before the beam intersection can be reached

from outside the danger zone.

Muting sensors MS3 and MS4 are not used.

WARNING!

Loss of safety function due to incorrect position of muting

sensors

Depending on the application, serious injury or death may result.

Ensure that you comply with the installation dimensions shown

in the figure overleaf.

AOPD

AOPD

MS1

MS2