The following operating modes can be implemented:

Sequential muting

Parallel muting

Cross muting

2.4.1

Terminology

Terminology

2-

Muting_Betriebsarten_Begriffsbestimmungen

Muting On

"Muting On" is the switch condition for switching on the muting func-

tion. When muting is switched on, the

Muting active

output parame-

ter has a 1 signal and time monitoring runs.

Muting Off

"Muting Off" is the switch condition for ending the muting function.

When the muting function is ended, output parameter

Muting active

has a 0 signal.

WARNING!

"During muting safe conditions shall be provided by other

means" (EN 954-1). For example, this may be achieved by the

conveyed item blocking access to the danger zone. Even open-

ings in or between the individual parts of the conveyor flow must

never enable access.

INFORMATION

You will find important additional information on the use of sen-

sors or contacts in the section entitled "Safety".