Operating modes
2
Muting
2.4
Operating modes
2400
Operating modes
2-
Muting_Betriebsarten
The following operating modes can be implemented:
Sequential muting
Parallel muting
Cross muting
2.4.1
Terminology
Terminology
2-
Muting_Betriebsarten_Begriffsbestimmungen
Muting On
"Muting On" is the switch condition for switching on the muting func-
tion. When muting is switched on, the
Muting active
output parame-
ter has a 1 signal and time monitoring runs.
Muting Off
"Muting Off" is the switch condition for ending the muting function.
When the muting function is ended, output parameter
Muting active
has a 0 signal.
WARNING!
"During muting safe conditions shall be provided by other
means" (EN 954-1). For example, this may be achieved by the
conveyed item blocking access to the danger zone. Even open-
ings in or between the individual parts of the conveyor flow must
never enable access.
INFORMATION
You will find important additional information on the use of sen-
sors or contacts in the section entitled "Safety".