Configuration in the PNOZmulti Configurator
2
Muting
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
2-6
2.3.6
Reset
Reset
2-
Muting_Konfiguration_Reset
Reset resets the muting element after a fault or during start-up if
no muting sensor is operated
and
the light curtain is clear.
2.3.7
Restarting the muting time
Restarting the muting time
2-
Muting_Konfiguration_Neustart der Muting-Zeit
Reset resumes muting and restarts the muting time if
muting was ended as a result of the muting time having elapsed (e.g.
by the conveyor feed stopping)
and
the muting sensors are returning feasible signals and the light curtain
has not been interrupted.
CAUTION!
The following additional safety requirements apply to the muting
override:
– The override switch must have a hold-to-run control device
(touch-operated switch).
– The override switch must be installed in a fixed position out-
side the danger zone.
– The danger zone and the muting station must be visible
from the override switch position.
– The danger zone must be identified as clear before the over-
ride switch is operated and while it is operated.
CAUTION!
The following additional safety requirements apply for the reset
button:
– The danger zone and the muting station must be visible
from the reset button position.
– The reset button may not be operated until the danger zone
has been viewed and has been identified as clear.