beautypg.com

6 reset, 7 restarting the muting time, 2muting – Pilz PNOZ m1p base unit User Manual

Page 14: 3 configuration in the pnozmulti configurator

background image

2.3

Configuration in the PNOZmulti Configurator

2

Muting

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

2-6

2.3.6

Reset

Reset

2-

Muting_Konfiguration_Reset

Reset resets the muting element after a fault or during start-up if

no muting sensor is operated

and

the light curtain is clear.

2.3.7

Restarting the muting time

Restarting the muting time

2-

Muting_Konfiguration_Neustart der Muting-Zeit

Reset resumes muting and restarts the muting time if

muting was ended as a result of the muting time having elapsed (e.g.

by the conveyor feed stopping)

and

the muting sensors are returning feasible signals and the light curtain

has not been interrupted.

CAUTION!

The following additional safety requirements apply to the muting

override:

– The override switch must have a hold-to-run control device

(touch-operated switch).

– The override switch must be installed in a fixed position out-

side the danger zone.

– The danger zone and the muting station must be visible

from the override switch position.

– The danger zone must be identified as clear before the over-

ride switch is operated and while it is operated.

CAUTION!

The following additional safety requirements apply for the reset

button:

– The danger zone and the muting station must be visible

from the reset button position.

– The reset button may not be operated until the danger zone

has been viewed and has been identified as clear.