2 switch conditions in cross mode, 3 diagnostic word, 2muting – Pilz PNOZ m1p base unit User Manual
Page 26: 4 operating modes
2.4
Operating modes
2
Muting
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
2-18
2.4.4.2
Switch conditions in cross mode
Switch conditions in cross mode
2-
Muting_Betriebsarten_Kreuz-Muting-Schaltbedingungen
Muting On
Muting sensors MS1 and MS2 must be operated within the configured
simultaneity period.
Muting Off
The suspension of the safety function is lifted when one muting sensor
at most is still operated.
2.4.4.3
Diagnostic word
Diagnostic word
2-
Muting_Betriebsarten_Muting-Diagnosewort
Messages can be queried in the PNOZmulti Configurator in bit mode
and linked further within the program.
Bit 1: Light curtain, interrupted (without active muting)
Bit 2: Waiting for reset (reset)
Bit 3: Sensor status unfeasible, override required
Bit 8: Muting time exceeded
Bit 9: Feasibility error, simultaneity period exceeded on muting sen-
sors 1 and 2, only one sensor operated