2.4

Operating modes

2

Muting

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

2-18

2.4.4.2

Switch conditions in cross mode

Switch conditions in cross mode

2-

Muting_Betriebsarten_Kreuz-Muting-Schaltbedingungen

Muting On

Muting sensors MS1 and MS2 must be operated within the configured

simultaneity period.

Muting Off

The suspension of the safety function is lifted when one muting sensor

at most is still operated.

2.4.4.3

Diagnostic word

Diagnostic word

2-

Muting_Betriebsarten_Muting-Diagnosewort

Messages can be queried in the PNOZmulti Configurator in bit mode

and linked further within the program.

Bit 1: Light curtain, interrupted (without active muting)

Bit 2: Waiting for reset (reset)

Bit 3: Sensor status unfeasible, override required

Bit 8: Muting time exceeded

Bit 9: Feasibility error, simultaneity period exceeded on muting sen-

sors 1 and 2, only one sensor operated