2.2

Safety

2

Muting

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

2-2

2.2

Safety

2200

Safety

2-

2.2.1

Intended use

Intended use

2-

Muting_Sicherheit_Bestimmungsgemäße Verwendung

The muting logic element is used to temporarily suspend safety func-

tions (ESPE/AOPD) without interrupting the process (muting) in accord-

ance with EN 61496-1. For a limited time period and a specific

operational phase (e.g. when feeding materials), it will suspend the ef-

fect of safety devices during the working process. Once completed, it

will reset the safety function.

Use of this operating mode and the arrangement of the sensors are ma-

chine or plant-specific and depend on the risk assessment of the ma-

chine or plant.

Be sure that you observe the warning notes given in the other parts of

this configuration guide and in the PNOZmulti technical catalogue.

These are highlighted visually through the use of symbols.

2.2.2

Standards

Standards

2-

Muting_Sicherheit_Normen

Knowledge of and compliance with the relevant standards and direc-

tives are a prerequisite for using the muting function. The following gives

an overview of the most important standards:

EN 61496-1: Safety of machinery – Electrosensitive protective equip-

ment

EN 60947-5-3: Low voltage switchgear and controlgear - Control cir-

cuit devices and switching elements

EN 999: Safety of machinery - The positioning of protective equip-

ment

Please note this is not an exhaustive list of safety standards and direc-

tives.

CAUTION!

Failure to observe the safety regulations in this configuration

guide and in the PNOZmulti technical catalogue will render the

warranty invalid.