3.2

Safety

3

Safety Mat/Safe Edge

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

3-2

3.2

Safety

3200

Safety

3-

3.2.1

Intended use

Intended use

3-

Schaltmatte_Sicherheit_Bestimmungsgemäße Verwendung

Base units from the configurable control system PNOZmulti and PNOZ-

multi Mini plus the expansion module PNOZ mi1p are suitable for con-

necting pressure-sensitive protective devices.

The units may only be used as a safety system in conjunction with the

approved pressure-sensitive protective devices (see certificate show-

ing approved pressure-sensitive protective devices).

The pressure-sensitive protective devices must be connected to the

inputs on the PNOZmulti units via the PSEN im1 interface or type

1N4007 diodes (see "Commissioning the safety system").

Only pressure-sensitive protective devices without installed terminat-

ing resistors are suitable.

The following are not permitted: Walking aids such as canes and

wheeled vehicles

The configurable control system PNOZmulti is used as a control unit

and as an output signal switching device in accordance with

EN 1760-1, 09/97.

3.2.2

Safety guidelines

Safety guidelines

3-

Schaltmatte_Sicherheit_Sicherheitshinweise

Do not install and commission the safety system until you have read and

understood this chapter, the technical catalogue and the installation

manual from the safety mat/safe edge manufacturer.

You must also be familiar with the applicable regulations for health and

safety at work and accident prevention.

In particular you should refer to EN 1760-1 and EN 1760-2.

In terms of faults the safety system complies with Category 3, PL d of

EN ISO 1349-1 and SIL CL 2 of EN IEC 62061. With the safety mat

it's important to consider Note 3 to Clause 4.15 of EN 1760-1

The categories for safety mats on machines in accordance with EN

13849-1 are specified in type C standards.

CAUTION!

When pressure-sensitive protective devices are connected to

PNOZmulti units, the units (including the coated version) may

only be operated at an ambient temperature of 0 to +60 °C.