Configuration in the PNOZmulti Configurator

2

Muting

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

2-4

2.3

Configuration in the PNOZmulti Configurator

2300

Configuration in the PNOZmulti Configurator

2-

2.3.1

Functions

Functions

2-

Muting_Konfiguration_Funktionen

Muting via light beam devices or limit switches

Override option in case of fault

Max. muting time can be set

Muting sensors can be monitored for simultaneity

Configuration of bounce time for contact-based muting sensors

Sequence of the muting sensors can be monitored

Operating modes

– Sequential muting

– Parallel muting

– Cross muting

2.3.2

Input parameters

Input parameters

2-

Muting_Konfiguration_Eingangsparameter

Muting sensor 1

N/O contact of muting sensor 1

Muting sensor 1 = 0: Not operated

Muting sensor 1 = 1: Operated

Muting sensor 2

N/O contact of muting sensor 2

Muting sensor 2 = 0: Not operated

Muting sensor 2 = 1: Operated

Light curtain

Light curtain = 0: Interrupted

Light curtain = 1: Not interrupted

Assign the light curtain input parameter to the output of the light cur-

tain function element. The light curtain function element must be

configured with an automatic reset.

Muting sensor 3

N/O contact of muting sensor 3

Muting sensor 3 = 0: Not operated

Muting sensor 3 = 1: Operated

Muting sensor 4

N/O contact of muting sensor 4

Muting sensor 4 = 0: Not operated

Muting sensor 4 = 1: Operated

Muting override

Muting override = 1: Suspend the muting function if a fault occurs

(override) to override the muting channel.

Reset = 0/1 pulse edge: Reset muting after an error or start the muting

time.