2muting, 4 operating modes – Pilz PNOZ m1p base unit User Manual
Page 19
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
2-11
2.4
Operating modes
2
Muting
Vehicle length W less than distance C between MS1 and MS4
As the vehicle passes through, the first muting sensor becomes clear
(MS1 upon entering, MS4 upon exiting) before the last muting sensor
has been operated.
MS1
MS2
MS3
MS4
Travel direction
0
0
0
0
1
0
0
0
1
1
0
0
1
1
1
0
1/0
1
1
1/0
0
1
1
1
0
0
1
1
0
0
0
1
0
0
0
0
MS1
MS2
MS3 MS4
AOPD
W < C
A
B
C
This manual is related to the following products: