2.4

Operating modes

2

Muting

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

2-10

2.4.2.3

Sequence errors

Sequence errors

2-

Muting_Betriebsarten_sequenzielles Muting-Sequenzfehler

The muting sensors must be operated in a specific sequence in sequen-

tial mode. Once a particular directional movement has started (entry or

exit), it must be fully completed. Any deviation from the sequence shown

causes the enable output (enable = 0) and the output parameter

Muting

active

to reset.

Vehicle length W greater than distance C between MS1 and MS4

All sensors are temporarily operated as the vehicle passes through. The

first muting sensor (MS1 upon entering, MS4 upon exiting) only be-

comes clear once all muting sensors have been operated.

MS1

MS2

MS3 MS4

AOPD

W > C

A

B

C