beautypg.com

2 preparing for operation, 3safety mat/safe edge, 5 commissioning the safety system – Pilz PNOZ m1p base unit User Manual

Page 33

background image

3.5

Commissioning the safety system

3

Safety Mat/Safe Edge

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

3-6

3.5.2

Preparing for operation

Preparing for operation

3-

Schaltmatte_Sicherheitssystem in Betrieb nehmen-betriebsbereitschaft herstellen

Connect the pressure-sensitive protective device to the test pulse

outputs and the inputs (in examples I0 to I3).

Please note:

Always connect the pressure-sensitive protective devices to the

PNOZmulti units via

– interface PSEN im1,

– diodes of type 1 N4003 ...1N4007,

– or via the terminal block with filter, order no. 774 195, 774 196.

0 V may not be connected to the terminal block!

Input circuit

Connecting one pressure-sensitive protective device,
max. area of pressure-sensitive protective device = 8 m

2

Connecting multiple pressure-sensitive protective devices,
permitted per dual-pole input: max. 5 pressure-sensitive
protective devices in series, max. area of pressure-sensi-
tive protective device = 8 m

2

T0/T2

T1/T3

I0
I1

PNOZmulti

PSEN im1

1.2

1.1

5.2

5.1

2

1

...

T0/T2

T1/T3

I1

I0

I3

I2

PSEN im1

1.2

1.1

5.2

5.1

2

1

PNOZmulti

1 ... max. 5

...

...

...