2 preparing for operation, 3safety mat/safe edge, 5 commissioning the safety system – Pilz PNOZ m1p base unit User Manual
Page 33
3.5
Commissioning the safety system
3
Safety Mat/Safe Edge
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
3-6
3.5.2
Preparing for operation
Preparing for operation
3-
Schaltmatte_Sicherheitssystem in Betrieb nehmen-betriebsbereitschaft herstellen
Connect the pressure-sensitive protective device to the test pulse
outputs and the inputs (in examples I0 to I3).
Please note:
Always connect the pressure-sensitive protective devices to the
PNOZmulti units via
– interface PSEN im1,
– diodes of type 1 N4003 ...1N4007,
– or via the terminal block with filter, order no. 774 195, 774 196.
0 V may not be connected to the terminal block!
Input circuit
Connecting one pressure-sensitive protective device,
max. area of pressure-sensitive protective device = 8 m
2
Connecting multiple pressure-sensitive protective devices,
permitted per dual-pole input: max. 5 pressure-sensitive
protective devices in series, max. area of pressure-sensi-
tive protective device = 8 m
2
T0/T2
T1/T3
I0
I1
PNOZmulti
PSEN im1
1.2
1.1
5.2
5.1
2
1
...
T0/T2
T1/T3
I1
I0
I3
I2
PSEN im1
1.2
1.1
5.2
5.1
2
1
PNOZmulti
1 ... max. 5
...
...
...