beautypg.com

3 parallel muting, 1 position of the muting sensors, 2muting – Pilz PNOZ m1p base unit User Manual

Page 21: 4 operating modes

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

2-13

2.4

Operating modes

2

Muting

2.4.3

Parallel muting

Parallel muting

2-

2.4.3.1

Position of the muting sensors

Position of the muting sensors

2-

Muting_Betriebsarten_paralleles Muting-Anordnung der Muting-Sensoren

Muting sensors MS1 and MS2/MS3 and MS4 must be positioned at

the same height to the left and right of the vehicle.

The vehicle length W must be greater than distance A between MS1

and MS3/MS2 and MS4.

The distance between the light curtain and the muting sensor must be

as short as possible.

MS3

AOPD

AOPD

MS1

MS2

MS4

W

A