3 parallel muting, 1 position of the muting sensors, 2muting – Pilz PNOZ m1p base unit User Manual
Page 21: 4 operating modes
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
2-13
2.4
Operating modes
2
Muting
2.4.3
Parallel muting
Parallel muting
2-
2.4.3.1
Position of the muting sensors
Position of the muting sensors
2-
Muting_Betriebsarten_paralleles Muting-Anordnung der Muting-Sensoren
Muting sensors MS1 and MS2/MS3 and MS4 must be positioned at
the same height to the left and right of the vehicle.
The vehicle length W must be greater than distance A between MS1
and MS3/MS2 and MS4.
The distance between the light curtain and the muting sensor must be
as short as possible.
MS3
AOPD
AOPD
MS1
MS2
MS4
W
A
This manual is related to the following products: