2 switch conditions in sequential mode, 2muting, 4 operating modes – Pilz PNOZ m1p base unit User Manual
Page 17
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
2-9
2.4
Operating modes
2
Muting
2.4.2.2
Switch conditions in sequential mode
Switch conditions in sequential mode
2-
Muting_Betriebsarten_sequenzielles Muting-Schaltbedingungen
Muting On
Entering the danger zone:
1. Muting sensors MS1 and MS2 must be operated consecutively (first
MS1, then MS2) within the configured simultaneity period. Muting is
activated by operating MS2.
2. Muting sensors MS3 and MS4 must be operated consecutively (first
MS3, then MS4) within the configured simultaneity period.
3. MS1 and MS2 must be cleared consecutively (first MS1, then MS2).
4. MS3 and MS4 must be cleared consecutively (first MS3, then MS4).
Leaving the danger zone:
1. Muting sensors MS4 and MS3 must be operated consecutively (first
MS4, then MS3) within the configured simultaneity period. Muting is
activated by operating MS3.
2. MS2 and MS1 must be operated consecutively (first MS2, then MS1).
3. MS4 and MS3 must be cleared consecutively (first MS4, then MS3).
4. MS2 and MS1 must be cleared consecutively (first MS2, then MS1).
Muting Off
Suspension of the safety function is cancelled as soon as the penulti-
mate muting sensor, MS2 or MS3, is no longer operated, i.e. only
one muting sensor remains operated.