beautypg.com

4 diagnostic word, 5 timing diagram (example), 2muting – Pilz PNOZ m1p base unit User Manual

Page 20: 4 operating modes

background image

2.4

Operating modes

2

Muting

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

2-12

2.4.2.4

Diagnostic word

Diagnostic word

2-

Muting_Betriebsarten_Muting-Diagnosewort

Messages can be queried in the PNOZmulti Configurator in bit mode

and linked further within the program.

Bit 1: Light curtain, interrupted (without active muting)

Bit 2: Waiting for reset (reset)

Bit 3: Sensor status unfeasible, override required

Bit 8: Muting time exceeded

Bit 9: Feasibility error, simultaneity period exceeded on muting sen-

sors 1 and 2, only one sensor operated

Muting_Betriebsarten_Muting-Diagnosewort-bit10-para-sequ

Bit 10: Feasibility error, simultaneity period exceeded on muting sen-

sors 3 and 4, only one sensor operated

2.4.2.5

Timing diagram (example)

Timing diagram (example)

2-

Muting_Betriebsarten_sequenzielles Muting-Zeitdiagramm

Vehicle length W less than distance C between MS1 and MS4

Key:

t

sync

= Simultaneity

t

MUT

= Muting time

: Set enable with reset
: Start muting via MS1/MS2
: End muting by clearing MS3
: Restart muting via MS1/MS2

1

0

1

Reset

1

0

1

0

1

0

1

0

1

0

3

2

4

MS1

MS2

Muting

Enable

AOPD

t

sync

t

sync

t

MUT

MS4

MS3

1

0

1

0