Side view - rdh, Rear view, Rear view of basic cabinet – Reznor RXH (Outdoor PreevA) Unit Installation Manual User Manual

Page 9: Side view - reh, Front view, Side view of optional modules

background image

Form I-RDH/REH/RHH/RXH (12-14), P/N 215210 R14, Page 9

Side View - RDH

Optional

Mixing Box

Blower Cabinet & Heat Section

E

Mounted

Height

6-1/4”

159mm

C

(length inside curb cap)

C1, C2

C3, C4

A5, A6

A

(length of system base)

Return

Air with

Optional

Mixing

Box only

Supply Air with Optional Downturn

3/4”(19 mm)

Duct Flange

Rear View

with Optional

Mixing Box

Rear View of

Basic Cabinet

(If basic unit only

optional outside air hood

is installed here, see page 25.)

F

G

J

H

9-1/16”

230mm

Inlet

Air

Inlet Air

with

Duct

Flange

3/4”(19 mm)

Duct Flange

D

(inside curb cap)

B

(width of base)

3-1/16”

77 mm

RDH &

RHH

cL

Combustion

Air*

Vent*

Gas Connnection*

Optional

Downturn

cL

cL

17-15/16”

455mm

P

9-1/4”

235mm

R

G

F

A1, A2

cL

cL

13-11/16”

348mm

13-11/16”

348mm

K, K1, or K2

3/4”(19 mm)

Duct Flange

G

F

Optional

Evap Cooling

Module

Optional Cooling Module

A3, A4

Rear View

with Optional

Evap Cooler, see page 32.

Side View - REH

Airflow

X

Optional

Downturn

Bottom View with Optional

Cooling Coil Module, Mixing Box,

and Downturn Plenum.

Rear Views

(Dimensions

apply to all

Models.)

Front View

NOTE: Side view of “no heat” Model RXH is not

illustrated but includes the blower section and heat

section cabinets less the heating components.

Dimensions here apply to “no heat” RXH only. For

RXH with hot water heat, see page 38.

NOTE: Model RHH must be mounted on a curb
and the area under the unit must be left open.

Blower

Electrical

Electric

Heat

Section

Electrical Supply

Inlet (pilot hole)

8-1/4

(210)

Side View of Optional Modules

Side View Dimensions A, C, E, and K are the

same for Models RDH, REH, & RXH (subject

to option availability). Model RHH side

dimensions are longer.

FIGURE 4 - Dimensions - Model RDH, REH, RHH and RXH (no heat only) with a Downturn Plenum

(bottom discharge)

NOTE: An optional evaporative cooling module (Option ECC) is always first and extends beyond the roof curb. It has no affect on

inside curb length Dimension

C or K.

Dimensions Specific to each Module:

Mixing Box (MXB), FIGURE 22, page 27.

Evaporative Cooling Module (ECC), FIGURE 25, page 32.

Chilled Water Cooling Coil Cabinet (AU6), FIGURE 31, page 35.

DX Cooling Coil Cabinet (AU5), FIGURE 32A, page 36.

DX Cooling Coil Cabinet with Reheat (AU7), FIGURE 32B, page 36.

Hot Water Heat Module for RXH, page 39, FIGURE 36A.

Other Dimensions:

All Configurations with Horizontal Discharge (no downturn plenum),

FIGURE 2, page 7.

Outside Air Hood (Option AS2), FIGURE 19A, page

25.

RDH Gas Heat, FIGURE 4 above and FIGURES

14A&B, page 22.

REH Electric Heat, SIDE VIEW in FIGURE 4 above .

RHH High Efficiency Model, FIGURE 2, page 7,

but with length dimensions from TABLE 4 that

include 27-1/2” (699) added for downturn plenum.

See

FIGURE 15, page 23, for heat section drain

connection location.