Form I-RDH/REH/RHH/RXH (12-14), P/N 215210 R14, Page 13

TABLE 8A - Dimensions and Weights of Optional Roof Curbs for Model RXH with Optional Hot

Water Heat Module (Option HW2)

Configuration*

Option

Code

RXH with Optional Hot

Water Heat Module

Inches (±1/8)

mm (±3)

Weight

A

B

C

D

A

B

C

D

lbs

kg

Model RXH with Optional Hot Water Heat

Module (HW2) and horizontal discharge

CJ8H

000A

68-5/8 29-13/16

64-7/8

26-1/16 1743

757 1648 662

115

52

000B

68-5/8 39-13/16

64-7/8

36-1/16 1743 1,011 1648 916

127

58

000C

84-3/8 29-13/16

80-5/8

26-1/16 2143

757 2048 662

134

61

000D

84-3/8

46-1/16

80-5/8

42-5/16 2143 1,170 2048 1,075 153

69

000E

84-3/8

54-1/16

80-5/8

50-5/16 2143 1,373 2048 1,278 153

69

Model RXH with Optional Hot Water Heat

Module (HW2) PLUS 1 either Downturn

Discharge Plenum (AQ5 or AQ8); OR Mixing

Box (MXB1) with horizontal discharge; OR

Cooling Coil Cabinet without Reheat (AU5

or AU6) with horizontal discharge

CJ8J

000A

96-3/8 29-13/16

92-5/8

26-1/16 2448

757 2353 662

148

67

000B

96-3/8 39-13/16

92-5/8

36-1/16 2448 1,011 2353 916

160

73

000C

112-1/8 29-13/16 108-3/8

26-1/16 2848

757 2753 662

167

76

000D

112-1/8 46-1/16

108-3/8

42-5/16 2848 1,170 2753 1,075 167

76

000E

112-1/8 54-1/16

108-3/8

50-5/16 2848 1,373 2753 1,278 167

76

Model RXH with Optional Hot Water Heat

Module (HW2) PLUS 2 - Down Discharge

(AQ 5 or AQ8) AND Mixing Box OR Cooling

Coil Cabinet without Reheat (AU 5 or 6);

OR Mixing Box AND Cooling Coil Cabinet

without Reheat (AU 5 or 6) with horizontal

discharge

CJ8K

000A

124-1/8 29-13/16 120-3/8

26-1/16 3153

757 3058 662

189

86

000B

124-1/8 39-13/16 120-3/8

36-1/16 3153 1011 3058 916

201

91

000C

139-7/8 29-13/16 136-1/8

26-1/16 3553

757 3458 662

208

94

000D

139-7/8 46-1/16

136-1/8

42-5/16 3553 1170 3458 1075

227

103

000E

139-7/8 54-1/16

136-1/8

50-5/16 3553 1373 3458 1278

237

108

Model RXH with Optional Hot Water Heat

Module (HW2) PLUS 3 - Down Discharge

Plenum (AQ5 or AQ8) AND Mixing Box

(MXB1) AND Cooling Coil Cabinet without

Reheat (AU5 or AU6)

CJ8L

000A

151-3/4 29-13/16

148

26-1/16 3854

757 3759 662

185

84

000B

151-3/4 39-13/16

148

36-1/16 3854 1011 3759 916

197

89

000C

167-3/8 29-13/16 163-5/8

26-1/16 4251

757 4156 662

204

93

000D

167-3/8 46-1/16

163-5/8

42-5/16 4251 1170 4156 1075

224

102

000E

167-3/8 54-1/16

163-5/8

50-5/16 4251 1373 4156 1278

234

106

Model RXH with Optional Hot Water Heat

Module (HW2) PLUS 1 -

Cooling Coil Cabinet with Reheat (AU7)

with horizontal discharge

CJ8M

000A

121-1/4 29-13/16 117-1/2

26-1/16 3080

757 2985 662

222

101

000B

121-1/4 39-13/16 117-1/2

36-1/16 3080 1011 2985 916

234

106

000C

136-7/8 29-13/16 133-1/8

26-1/16 3477

757 3381 662

241

109

000D

136-7/8 46-1/16

133-1/8

42-5/16 3477 1170 3381 1075

261

118

000E

136-7/8 54-1/16

133-1/8

50-5/16 3477 1373 3381 1278

271

123

Model RXH with Optional Hot Water Heat

Module (HW2) PLUS 2 -

Cooling Coil Cabinet with Reheat (AU7)

AND Down Discharge Plenum (AQ5 or AQ8)

OR Mixing Box (MXB1) with horizontal

discharge

CJ8N

000A

148-7/8 29-13/16 145-1/8

26-1/16 3781

757 3686 662

219

99

000B

148-7/8 39-13/16 145-1/8

36-1/16 3781 1011 3686 916

231

105

000C

164-5/8 29-13/16 160-7/8

26-1/16 4181

757 4086 662

238

108

000D

164-5/8 46-1/16

160-7/8

42-5/16 4181 1170 4086 1075

258

117

000E

164-5/8 54-1/16

160-7/8

50-5/16 4181 1373 4086 1278

267

121

Model RXH with Optional Hot Water Heat

Module (HW2) PLUS 3 -

Cooling Coil Cabinet with Reheat (AU7)

AND Down Discharge Plenum (AQ5 or AQ8)

AND Mixing Box (MXB1)

CJ8P

000A

176-3/4 29-13/16

173

26-1/16 4489

757 4394 662

252

114

000B

176-3/4 39-13/16

173

36-1/16 4489 1011 4394 916

265

120

000C

192-3/8 29-13/16 188-5/8

26-1/16 4886

757 4791 662

271

123

000D

192-3/8 46-1/16

188-5/8

42-5/16 4886 1170 4791 1075

291

132

000E

192-3/8 54-1/16

188-5/8

50-5/16 4886 1373 4791 1278

301

137

Model and Size

Dimensions (inches ±1/8)

Dimensions (mm ±3)

RDH

REH

RXH

(without

hot

water

heat

module)

F

H

K (with mixing box and

down discharge)

F

H

K (with mixing box and

down discharge

)

(with mixing box

and/or down

discharge)

no

cooling

coil

module

with a cooling coil

module

(with mixing

box and/

or down

discharge)

no

cooling

coil

module

with a cooling

coil module

no

reheat

with

reheat

no

reheat

with

reheat

75/100

10A/20A/40A

000A

22-7/8 1-9/16 81-5/8 109-3/8 134-3/8 581

40

2073

2778

3413

125/150

15B/30B/60B

000B

26-1/2

4-3/4

81-5/8 109-3/8 134-3/8 673 121

2073

2778

3413

175/200/ 225

N/A

000C

22-7/8 1-9/16 97-3/8 125-1/8 150-1/8 581

40

2473

3178

3813

250/300

30D/60D/90D/

120D

000D

34-3/4

3-3/4

97-3/8 125-1/8 150-1/8 883

96

2473

3178

3813

350/400A

40E/80E/120E

000E 45-13/16 2-1/4

97-3/8 125-1/8 150-1/8 1164 57

2473

3178

3813

TABLE 7B - Dimensions

for Locations of Bottom

Duct Openings as

shown in FIGURE 8 for

Models in TABLE 7A

NOTE: Duct openings should

be 1” larger than the duct size

for installation clearance.

TABLE 8B - Dimensions

for Locations of Bottom

Duct Openings as

shown in FIGURE 8 for

Models in TABLE 8A

NOTE: Duct openings should

be 1” larger than the duct size

for installation clearance.

Model RXH

(with hot

water heat

module)

Dimensions (inches ±1/8)

Dimensions (mm ±3)

F

H

K (with mixing box & downturn)

F

H

K (with mixing box & downturn)

(with mixing box

and/or down

discharge)

no cooling

coil module

with a cooling coil

module

(with mixing box

and/or down

discharge)

no cooling

coil

module

with a cooling coil

module

no reheat with reheat

no reheat with reheat

000A

22-7/8

1-9/16

98-7/16

126-3/16

151-3/16

581

40

2500

3205

3840

000B

26-1/2

4-3/4

98-7/16

126-3/16

151-3/16

673

121

2500

3205

3840

000C

22-7/8

1-9/16

114-3/16

141-15/16 166-15/16

581

40

2900

3605

4240

000D

34-3/4

3-3/4

114-3/16

141-15/16 166-15/16

883

96

2900

3605

4240

000E

45-13/16 2-1/4

114-3/16

141-15/16 166-15/16

1164

57

2900

3605

4240

**

Model RXH in Tables 7A and 7B apply to “no heat” model only. For roof curb for Model RXH with optional hot water heat module, see Tables

8A and 8B

* See Configurations in Paragraph 4.2.

NOTE: If there is an evaporative cooling module, the base of the unit under the evaporative cooling

module extends beyond the end of the roof curb. An evaporative cooling module does not affect the length of the roof curb.