Wiring diagram option identification – Reznor RXH (Outdoor PreevA) Unit Installation Manual User Manual

Page 65

background image

Form I-RDH/REH/RHH/RXH (12-14), P/N 215210 R14, Page 65

Wiring Diagram

Option Identification

The Option Codes for these electrical options are shown on the wiring diagram. Cus-

tom diagram lists only the options ordered.

Option

Code

Brief Description

AG1

Analog Heating Control - 1-Stage

AG2

Analog Heating Control - 2-Stage

AG3

Analog Heating/Makeup Air - 2-Stage unit-mounted ductstat

AG15

Analog Heating/Makeup Air - 2-Stage remote ductstat w/dial

AG16

Analog Heating/Makeup Air - same as AG15 with display

AG40

Analog Heating/Makeup Air - converts to digital for field supplied BMS

AG58

Analog Heating/Makeup Air - electronic modulation 8:1 turndown

AG60

Analog Heating/Makeup Air - same as AG3 plus 33% low fire

AG61

Analog Heating/Makeup Air - same as AG15 plus 33% low fire

AG62

Analog Heating/Makeup Air - same as AG61 with display

AK1

115/1 Supply Voltage

AK2

208/1 Supply Voltage

AK3

230/1 Supply Voltage

AK5

208/3 Supply Voltage

AK6

230/3 Supply Voltage

AK7

460/3 Supply Voltage

AK8

575/3 Supply Voltage

AL2

1/4 HP 1725 RPM open dripproof motor

AL3

1/3 HP 1725 RPM open dripproof motor

AL4

1/2 HP 1725 RPM open dripproof motor

AL5

3/4 HP 1725 RPM open dripproof motor

AL6

1 HP 1725 RPM open dripproof motor

AL7

1-1/2 HP 1725 RPM open dripproof motor

AL8

2 HP 1725 RPM open dripproof motor

AL9

3 HP 3600 RPM open dripproof motor

AL10

5HP 3600 RPM open dripproof motor

AL19

1/4 HP 1725 RPM totally enclosed motor

AL20

1/3 HP 1725 RPM totally enclosed motor

AL21

1/2 HP 1725 RPM totally enclosed motor

AL22

3/4 HP 1725 RPM totally enclosed motor

AL23

1 HP 1725 RPM totally enclosed motor

AL24

1-1/2 HP 1725 RPM totally enclosed motor

AL25

2 HP 1725 RPM totally enclosed motor

AL26

3 HP 3600 RPM totally enclosed motor

AL27

5 HP 3600 RPM totally enclosed motor

AN2

Contactor, IEC

AN10

Motor Starter with Overloads

AR8

On/Off Damper (no mixing box)

AU7

Cooling Coil Cabinet with DX Coil and Reheat Pump

AUR1

Modulating Reheat

BA6

Disconnect Switch - Flush-mounted, lockable, non-fusible

BC2

Convenience Outlet (requires separate power supply)

BD4

Firestat, 200°F

BD5

Firestat, 200°F (field installed)

BE2

Low Limit, Discharge Temperature

BF14

Phase Loss/Low Voltage Protection - with AK5, AK6, AK7 only

BF15

Phase Loss/Phase Reversal Protection - 3 phase only

BG7

Plugin DPDT Relay - Specified operation

BG9

Plugin DPDT Relay - Exhaust Fan Interlock

BHB1

Time Clock Card - with DG 1, 2, 5, 6

BHB2

N2 Card - with DG 1, 2, 5, 6 and D12 B, C, D, E, F, G

BHB3

LonMark Card - with DG 1, 2, 5, 6 and D12 B, C, D, E, F, G

BN2

Limit Control - High Ambient (burner cutoff)

BP2

Gas Pressure Safety Switch, High

BP3

Gas Pressure Safety Switch, Low

BP4

Gas Pressure Safety Switches, High and Low

CL1

Thermostat - 1-stage heat, 24V, 40-80°F

CL3

Thermostat - 1-stage heat, 24V, 40-90°F

CL8

Thermostat - 2-stage heat/cool, 24V, 40-90°F, non-programmable

CL33

Thermostat - 2-stage heat/cool, 24V, programmable

CL36

Thermostat - Modulating Heat/cool with 3-stage cooling

Option

Code

Brief Description

CL52

Thermostat - 1-stage heat/cool, 24V, 45-88°F, programmable 5/2 day

CL67

Space Temperature Sensor/Override - with D12 B, C, D, E

CT1

Evap Cooler Fill & Drain Kit - 120/1 with AK1, AK7, AK8

CT2

Evap Cooler Fill & Drain Kit - 208/1 with AK2, AK5

CT3

Evap Cooler Fill & Drain Kit - 240/1 with AK3, AK6

CT5

Evap Cooler Freeze Protection - AquaSaver controls

CT6

Evap Cooler Freeze Protection - with CT 1, 2, or 3

D12B

Digital Control w/FX06 - Neutral Air/Discharge Air Temp Control

(applies to RDH with or without reheat)

D12C

Digital Control w/FX06 - Space Temp Cntrl w/Discharge Air Reset

(applies to RDH with or without reheat)

D12D

Digital Control w/FX06 - Neutral Air/Discharge Air Temp Control

(applies to REH with SCR (modulating) heating control and 3-stage

cooling with or without reheat)

D12E

Digital Control w/FX06 - Recirculating Air Temp Control (applies to

REH with 2-stage heating and 3-stage cooling with or without reheat)

(not recommended for makeup air)

DF12

Digital Control w/FX06 - Space Temperature, 2-stage heating / 3-stage

cooling (applies to RHH)

D12G

Digital Control w/FX06 - Gas-fired electronic modulation with 8:1 turn-

down; 3-stage cooling; with or without reheat; discharge air tempera-

ture control

DG1

Digital Control w/FX05 - Space Temperature, 2-stg heating/3-stg cool-

ing (applies to RDH without reheat)

DG2

Digital Control w/FX05 - Space Temperature elec mod htg/3-stg clng

(applies to RDH without reheat)

DG5

Digital Control w/FX05 - Discharge Air Temperature, 2-stg htg/3-stg

clng (applies to RDH without reheat)

DG6

Digital Control w/FX05 - Discharge Air Temperature elec mod htg/3 stg

clng (applies to RDH without reheat)

ECD1

Evap Cooler AquaSaver meter water flow system

EG1

Analog Heating Control - 1 Stage thermostat

EG2

Analog Heating Control - 2 Stage thermostat

GE3

Damper Control - Outside air, 2-position motor

GE5

Damper Control - Outside air, 3-position motor

GE6

Damper Control - Outside & Return, 2-position motor

GE7

Damper Control - Outside & Return, 2-position mtr w/warmup

GE8

Damper Control - Outside & Return, 3-position, unit potentiometer

GE10

Damper Control - Outside & Return, 3-position, remote potentiometer

GE11

Damper Control - Outside & Return, modulating, mixed air

GE12

Damper Control - Outside & Return, modulating, mixed air w/min

GE13

Damper Control - Outside & Return, modulating, mixed air w/warmup

GE14

Damper Control - Outside & Return, mod, mixed air w/min & warmup

GE15

Damper Control - Outside & Return, modulating, building pressure

GE16

Damper Control - Outside & Return, modulating, BMS control

GE21

Damper Control - Outside & Return, modulating, enthalpy

GE22

Damper Control - Outside & Return, modulating, dual reference

enthalpy

SA1

Duct Photoelectric Smoke Detector

T4 XX Thermal Expansion Valve (R410A only)
UV2

Germicidal Lamp

VFD1

Variable Frequency Drive

VFD2

Variable Frequency Drive (requires field installation)