0 mechanical (cont’d), 2 cooling coil module dimensions (cont’d), Ab c – Reznor RXH (Outdoor PreevA) Unit Installation Manual User Manual

Page 36: Inlet air view, Side view

background image

Form I-RDH/REH/RHH/RXH (12-14), Page 36

A

B

C

ø 3/8” Hot Gas Bypass

ø 7/8” Liquid Lines

ø 1-3/8”

Suction

Lines

1” MPT

Drain

13-1/2”(343mm)

15-1/2”(394mm)

16-7/8”(429mm)

27-1/4”(692mm)

12-1/2”(318mm)

10-9/32”(261mm)

7-13/16”(198mm)

1-5/32”

(29mm)

Inlet Air

View

(factory attached to

optional mixing

box or evaporative

cooling module or

location for field-

installed hood)

This

end is

atached

to the

blower

cabinet

at the

factory.

Side

View

Airflow

FIGURE 32A -

Dimensions of

DX Cooling Coil

Cabinet without

Reheat, Option

AU5

TABLE 23A -

Dimensions of DX

Cooling Coil Cabinet without

Reheat (inches and mm)

Model RDH

Model REH

Model

RHH Model RXH

A

B

C

A

B

C

Dimensions (inches)

Dimensions (mm)

75/100/125/150

10A/20A/40A/15B/30B/60B

--

000A/000B

31-9/16 25-9/16 22-1/16 801 649 560

175/200/225/250/300/350/400A 30D/60D/90D/120D/40E/80E/120E All

000C/000D/000E 40-13/16 34-13/16 23-5/16 1037 884 592

A

1-1/16”

(27mm)

3-13/32”

(87mm)

D

3-5/8”

(92mm)

B

C

Filter/

Compressor

Access

Coil Access

56-1/2” (1435mm)

55-5/32” (1401mm)

Liquid Line Grommets

(Cross slit at installation time.)

Hot Gas

Bypass Grommets

(Cross slit at installation time.)

H

G

F

E

10-5/16” (262mm)

7-7/8” (200mm)

12-9/16” (319mm)

1” NPT Drain Fitting

Suction Lines

31-9/16” (802mm)

34-9/16” (878mm)

43” (1092mm)

52” (1321mm)

56-1/4” (1429mm)

2-1/2”

(64mm)

FIGURE 32B - Dimensions of DX Cooling Coil Cabinet with Reheat, Option AU7

TABLE 23B -

Dimensions of DX

Cooling Coil Cabinet with

Reheat (inches and mm)

Model RDH

Size

Model REH Size

Model

RHH

Model

RXH

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

Dimensions (inches)

Dimensions (mm)

75/100

10A/20A/40A

N/A

000A 33-3/4 33-13/16

27

24

15-3/4 22 26-1/4 32-1/2 857

859 686 610 400 559 667 826

125/150

15B/30B/60B

N/A

000B 43-3/4 43-13/16

37

24

15-3/4 22 26-1/4 32-1/2 1111 1113 940 610 400 559 667 826

175/200/225 N/A

130/180 000C 33-3/4 33-13/16

27

33-1/4 17-3/4 24 30-1/4 36-1/2 857

859 686 845 451 610 768 927

250/300

30D/60D/90D/120D 260

000D

50

50-5/32 43-1/4 33-1/4 17-3/4 24 30-1/4 36-1/2 1270 1274 1099 845 451 610 768 927

350/400A

40E/80E/120E

350

000E

58

58-5/32 51-1/4 33-1/4 17-3/4 24 30-1/4 36-1/2 1473 1503 1302 845 451 610 768 927

If the cooling module was ordered with an optional ultra-violet light, the fixture is factory

installed but the bulb and other components are shipped in the blower compartment for

field installation. Follow the instructions on the option installation form shipped in the

parts bag. Option UV2 ultra-violet light requires its own power supply and disconnect

switch.

6.6.3 Ultra-Violet Light,

Option UV2

CAUTION: Do not touch bulb glass without gloves. Oil from fingerprints

will permanently etch bulb and weaken structure. Clean bulb after

handling.

WARNING

Do not use UVC lights for service lighting. Never expose eyes or

skin to ultra-violet light from any source.

6.0 Mechanical

(cont’d)

6.6.2 Cooling Coil Module Dimensions (cont’d)

6.6 Optional Cooling Coil Module (factory installed) (cont’d)