0 clearances and dimensions, 1 clearances – Reznor RXH (Outdoor PreevA) Unit Installation Manual User Manual
Page 5
Form I-RDH/REH/RHH/RXH (12-14), P/N 215210 R14, Page 5
Field-Installed Accessories
- If your unit was ordered with Option UV2, UVC lights
in the cooling coil module, the bulbs and a box of parts are shipped in the blower com-
partment for field installation. Being careful not to touch the bulbs, verify the compo-
nents with the instruction sheet included with the parts.
Before beginning installation, be sure that all shipped-separate options ordered are
available at the site. Field-installed, shipped-separate options could include a roof
curb, an outside air hood, a vent cap, an energy recovery unit, a VFD, a thermostat
or other wall-mounted control, a remote console, a disconnect switch, a fill and drain
or freeze protection kit, a water hammer arrestor, a firestat, and/or a smoke detector.
Storage and Startup -
If this unit is going to be stored, take precautions to prevent
condensate formation inside the electrical compartments and motors. To prevent dam-
age to the unit, do not store sitting on the ground.
After the system has been moved to its installation site, remove all of the shipping
brackets and check the blower for free movement. See the check lists in Paragraph 9.0
before starting the unit and completing the Startup Form.
TABLE 1- Shipped-Separate or Shipped-Loose Components for Factory-Installed Options
4.0 Clearances and
Dimensions
4.1 Clearances
For safety and convenience, provide clearances as shown in the following table.
Clearance to combustibles is defined as the minimum distance from the heater to a
surface or object that is necessary to ensure that a surface temperature of 90°F above
the surrounding ambient temperature is not exceeded. Minimum clearances are also
listed on the heater rating plate.
TABLE 2A - Minimum
Clearances from
Combustible Material
Recommended Service Clearances by Model and Size
Model and Size
Control Side
Side
Opposite
Controls
Top
RDH
REH
RHH
RXH
Control Side
(Basic)
Control Side with
Mixing Box
Control Side with
Cooling Coil*
inches
mm
inches
mm
inches
mm
inches
mm
inches
mm
75/100
10A/20A/30A
--
000A
30
762
30
762
42
1067
6
152
18
457
125/150
15B/30B/60B
--
000B
34
864
34
864
52
1321
6
152
18
457
175/200/ 225
N/A
130/180 000C
30
762
30
762
42
1067
6
152
24
610
250/300
30D/60D/90D/120D
260
000D
42
1067
42
1067
58
1473
6
152
24
610
350/400A
40E/80E/120E
350
000E
52
1321
52
1321
66
1676
6
152
24
610
Minimum Clearances to Combustibles - ALL Sizes of Models RDH, REH, RHH
Control Side Side Opposite Controls
Front
Rear
Top
Bottom
inches
20
6
48
18
6
0
mm
508
152
1219
457
152
0
TABLE 2B - Recommended Service Clearances
*Clearance is
required for sliding out drain pan.
Factory-Installed
Option
Option Parts Requiring Installation (Parts are either shipped loose with the heater or shipped separately.)
AG3, AG60
On/Off Control Switch,
P/N 39732; Discharge Air Sensor Holder, P/N 115850; Discharge Air Sensor Holder Bracket,
P/N 213612
AG15, AG61
On/Off Control Switch,
P/N 39732; Remote Ductstat Temperature Selector, P/N 115848; Stage Adder Module(s),
P/N 115849; Discharge Air Sensor Holder, P/N 115850; Discharge Air Sensor Holder Bracket, P/N 213612
AG16, AG62
On/Off Control Switch,
P/N 39732; Remote Temperature Selector, P/N 115848; Stage Adder Module(s), P/N 115849;
Digital Temperature Display,
P/N 115852; Discharge Air Sensor Holder, P/N 115850; Discharge Air Sensor Holder
Bracket,
P/N 213612
DG1, DG2
Room Command Module,
P/N 211423
DG5, DG6
Room Command Module,
P/N 211424; Discharge Air Sensor Holder, P/N 115850; Discharge Air Sensor Holder
Bracket,
P/N 213612
AG58, D12B, D12C,
D12D, D12E, D12G Discharge Air Sensor Holder, P/N 115850; Discharge Air Sensor Holder Bracket, P/N 213612
GE10
Potentiometer,
P/N 16110
GE15
Pressure Null Switch,
P/N 88052
GE21
Enthalpy Sensor and Parts to install,
P/N 220686
GE22
Two Enthalpy Sensors and Parts to install, (2)
P/N 220686
AU7L, AU7R
Duct Humidity/Temperature Sensor,
P/N 206081; Mounting Bracket, P/N 207499
(
NOTE: These will be factory installed if mixing box, Option MXB1, is ordered.)