3 dimensions - optional cooling coil cabinet – Reznor RPBL Unit Installation Manual User Manual
Page 7
Form I-SSCBL/RPBL, P/N 149159 R7, Page 7
DX Coil Cabinet - Option AU3
for RPBL and SSCBL and
Options AU13 and AU14 for
RPBL only
Discharge Damper Note:
Optional two-position dis-
charge dampers in Option
AU12 or AU14 fit in the
discharge air opening. The
damper motor fits inside
the downturn cabinet. See
field wiring instructions in
Paragraph 6.3.6.
Dimensions (all AU coil cabinets)
Downturn
Plenum Cabinet
(factory
attached)
FIGURE 4 - Optional Cooling
Coil Cabinets with DX or
Chilled Water Coil, with and
without Downturn Plenum
Cabinet
NOTE: For the length of a Model RPBL with a cooling
coil cabinet, see the table on the right. Cooling coil
cabinet is shipped separately and attached in the field.
See page 11 for roof curb dimensions.
Total length of an indoor system with a cooling coil
cabinet depends on how the system is installed. If the
blower/furnace is suspended, a special curb cap and a
field-installed transition duct are required. Contact your
Sales Representative to receive specific information.
If an indoor system is mounted, add the cabinet length
to the blower/furnace length on page 5.
D
7/8 (22)
7/8 (22)
2 (51)
Side View
DX Coil
Cabinet
Drain Pan
Outlet
(1 FPVC)
Suction Line
Connection
(1-5/8 or 2-1/8)
14-1/2
(368)
6-5/8
(168)
G
F
(Inside of Curb Cap)
E
(Curb Cap Length)
Liquid Line
Connection Knockouts
(alternate locations)
2-3/8
(60)
3-1/2(89)
3-1/4(83)
Bottom View
DX Coil
Cabinet
Coil
Header
Housing
Side View
Optional
Downturn
Plenum
Cabinet
4-1/4
(108)
19-1/2 (495)
Discharge Air
H
(Discharge Air)
C
Side View
of Downturn
Plenum Cabinet
in Options
AU11, 12, 13
and 14 for
Model RPBL
4-1/4
(108)
4-1/4
(108)
Front View
of Downturn
Plenum Cabinet
in Options
AU11, 12, 13
and 14 for
Model RPBL
Front View
DX Coil
Cabinet with
Horizontal
Discharge
(Option AU3)
Liquid Line
Connections
(7/8 or 1-3/8)
5-1/8 (130)
8 (203)
3/4
(19)
3/4
(19)
A
B
3/4
(19)
18
(457)
44-1/4
(1124)
12-1/2
(318)
16-1/4
(413)
C
11-1/4
(286)
Side View
Chilled
Water Coil
Cabinet
F
(Inside of Curb Cap)
E
(Curb Cap Length)
D
7/8 (22)
Supply
Connection
2-1/2 NPT
G
7/8 (22)
Return
Connection
2-1/2 NPT
Coil Vent
1/2 NPT
Coil Drain
Connection
1/2 NPT
Drain Pan
Connection
1 FPVC)
6-5/8
(168)
38-3/8
(975)
15-1/4
(387)
Front View
CW Coil
Cabinet w/
Horizontal
Discharge
(Option
AU2)
44-1/4
(1124)
18
(457)
3/4
(19)
11-1/4
(286)
C
A
B
3/4
(19)
SSCBL or RPBL
Size
500,
600
700,
1050
400, 800,
1200
A
inches
47-3/4 53-1/4
58-3/4
mm
1213
1353
1492
B
inches
34-1/2
40
45-1/2
mm
876
1016
1156
C
inches
45-1/8 50-5/8
56-1/8
mm
1146
1286
1426
D
inches
56-3/8
62
67-3/8
mm
1432
1575
1711
E
Without
Downturn
inches
59-3/8 64-7/8
70-3/8
mm
1508
1648
1788
With
Downturn
inches
83-3/8 88-7/8
94-3/8
mm
2118
2257
2397
F
Without
Downturn
inches
57-3/8
63
68-3/8
mm
1457
1600
1737
With
Downturn
inches
81-3/8
87
92-3/8
mm
2067
2210
2346
G
inches
29-1/8 31-7/8
34-5/8
mm
740
810
879
H
inches
45-1/8 50-5/8
56-1/8
mm
1146
1286
1426
RPBL
Size
Width of Cabinet (not curb) Length of Cabinet (not curb)
w/Chilled Water
Coil Cabinet
w/DX Coil
Cabinet
w/Cooling Coil
Cabinet only
w/Cooling Coil
Cabinet w/Downturn
inches
mm
inches
mm
inches
mm
inches
mm
400
58-7/8 1495 66-7/8 1698 150-3/8 3820 173-1/2
4407
500, 600 47-1/8 1197 55-1/8 1400 165-3/8 4201 188-1/2
4788
700
53-3/8 1356 61-3/8 1559
171
4343 194-1/8
4931
800
58-7/8 1495 66-7/8 1698 176-3/8 4480 199-1/2
5067
1050
53-3/8 1356 61-3/8 1559
197
5004 220-1/8
5591
1200
58-7/8 1495 66-7/8 1698 202-3/8 5140 225-1/2
5728
4.1.3 Dimensions - Optional Cooling Coil Cabinet
Chilled Water Coil Cabinet - Option AU2 for RPBL and
SSCBL and Options AU11 and AU12 for RPBL only