16 full write access to parameters, 1 request, 2 answer – ebm-papst ECI-63.XX-K4 User Manual
Page 91: 3 error flags, 17 request jump back to bootloader, 9 rs485 communication

91
9 RS485 Communication
9.16 Full write access to parameters
9.16.1 Request
RS485 Char
Use
Value / Comment
1
Start byte
UART_CRX_CUSTOMER_ACCESS
2
Address byte
Bus address
3…6
Data 01…04 (AccessKey)
Customer access key
7
Checksum
9.16.2 Answer
RS485 Char
Use
Value / Comment
1
Start byte
UART_CTX_CUSTOMER_ACCESS
2
Address byte
Bus address
3
Status byte
4
Checksum
9.16.3 Error flags
Bit
Meaning
7
6
5
4
Incorrect access key, access is restricted
9.17 Request jump back to bootloader
The jump back into the bootloader is made after transferring the response.
9.17.1 Request
RS485 Char
Use
Value / Comment
1
Start byte
COM_CRX_BACK_TO_BOLO
2
Address byte
Bus address
3…6
Data 01…04 (AccessKey)
Customer access key
7
Checksum
This manual is related to the following products: