10 Parameter Description

Parameter 0x33: Current signal delta hysteresis

Description: Parameter is to be understood as being an absolute delta value, which specifies the absolute threshold “current signal threshold – hysteresis

current signal delta”.
E.g.:
Current signal threshold = 7000 mA
Hysteresis current signal delta = 1000 mA
Here the lower hysteresis threshold of the current signal is therefore 6000 mA = (7000 – 1000)

Parameter 0x34: Current time constant

Description: Delay, which must at least have expired in order for a current signal to be output.

Parameter 0x35: Current gating time

Description: Startup delay, which must at least have expired once on starting a drive in order for a current signal to be output.

Parameter 0x36: Reversing threshold

Description: The reversing threshold is a speed threshold. Above this threshold the current limits within the regenerative range are set to 0. If the actual

speed is below this threshold the drive will be able to move into the regenerative range, only then do the Imax limits for regenerative mode apply.

Parameter 0x37: Reversing threshold delta hysteresis

Description: Parameter is to be understood as being an absolute delta value from the reversing threshold, which specifies the absolute threshold “reversing

threshold – hysteresis reversing threshold delta”.
E.g.:
Reversing threshold = 100 rpm
Hysteresis start-stop threshold delta = 25 rpm
Here the lower hysteresis threshold of the reversing threshold is therefore 75 rpm = (100 – 25)

Parameter 0x38: I_Max_treibend_Rechts

Description: Maximum current for the driving clockwise rotation.

Parameter 0x39: I_Max_treibend_Links

Description: Maximum current for the driving counter-clockwise rotation.