beautypg.com

7 parameterisation of the operating modes – ebm-papst ECI-63.XX-K4 User Manual

Page 66

background image

66

7 Parameterisation of the Operating Modes

7.30 Operating mode 76: Speed setpoint PWM; rotational direction

NOTe

In order for the parameter to function, KP_H must be > 0.

Function IN 1:

Input for PWM signal.

Function IN 2:

Selecting the rotational direction.

Speed

Current limit

IN A

IN B

IN 1

IN 2

Direction

Value

Type

Value

Function

Comment

0

0

x

x

-

0

-

-

Free-wheeling

No braking, no current feed

1

0

PWM

0

pos

PWM

S

P

N control

1

0

PWM

0

pos

PWM

S

P

N control

1

0

PWM

1

neg

PWM

S

P

N control

1

0

PWM

1

neg

PWM

S

P

N control

0

1

PWM

0

neg

PWM

S

P

N control

0

1

PWM

0

neg

PWM

S

P

N control

0

1

PWM

1

pos

PWM

S

P

N control

0

1

PWM

1

pos

PWM

S

P

N control

1

1

PWM

0

-

0

S

P

Stop

Braking and stopping

1

1

PWM

0

-

0

S

P

Stop

Braking and stopping

1

1

PWM

1

-

0

S

P

Stop

Braking and stopping

1

1

PWM

1

-

0

S

P

Stop

Braking and stopping

Stop control =

If KP_H > 0; brake and stop in the current position on changeover to IN A = IN B = 1 + Coasting rh, lh.

If KP_H = 0; brake and stop on changeover to IN A = IN B = 1, run speed to 0.

S = Static
P = Parameter
F = Freeze
D = Dynamic
x = Arbitrary value

This manual is related to the following products: