beautypg.com

3 “default” memory area, 6 parameterisation – ebm-papst ECI-63.XX-K4 User Manual

Page 31

background image

31

6 Parameterisation

6.1.3 “default” memory area

The default values loaded in the factory are stored in the “default” memory area. The operating data can be reset to the as-delivered
condition by using the “reload” command. The data is written in the “custom” and “RAM” areas.

Access to parameterisation with “customer access key” (password).

“Kickstart”

RS485

Drive memory area

external

RAM

custom

default

Parameter

(application

function)

Parameter

(application

function)

reload

Parameter

(application

function)

write

store

Parameter

(application

function)

read

power up

reload

Parameter

(application

value)

Parameter

(application

value)

reload

Parameter

(application

value)

write

store

Parameter

(application

value)

read

power up

reload

Parameter

(HW set val)

Parameter

(HW set val)

power up

Parameter

(HW set val)

Parameter

(HW set val)

Parameter

(Offset single

sensor)

power up

Parameter

(Offset single

sensor)

Parameter

(Offset single

sensor)

Blue arrow = Command is executed in the operational status (clockwise, counterclockwise, braking / positioning)
Black arrow = Command is executed in the state unlock (motor in freewheel)

NOTe

With the command „Save“, the „user access key“ is reseted.

The “store” command is used to reset the “customer access key”.

This manual is related to the following products: