26 operating mode 68: rotational direction; brake, 7 parameterisation of the operating modes – ebm-papst ECI-63.XX-K4 User Manual
Page 62

62
7 Parameterisation of the Operating Modes
7.26 Operating mode 68: Rotational direction; brake
NOTe
In order for the parameter to function, KP_H must be > 0.
Function IN 1:
Selecting the rotational direction.
Function IN 2:
Input for braking voltage; motor only runs if brake released.
Speed
Current limit
IN A
IN B
IN 1
IN 2
Direction
Value
Type
Value
Function
Comment
0
0
x
x
-
0
-
-
Free-wheeling
No current feed
1
0
0
0
-
0
S
P
Free-wheeling
1
0
1
0
-
0
S
P
Free-wheeling
1
0
0
1
pos
A1
S
P
N control
1
0
1
1
neg
A1
S
P
N control
0
1
0
0
-
0
S
P
Free-wheeling
0
1
1
0
-
0
S
P
Free-wheeling
0
1
0
1
neg
A1
S
P
N control
0
1
1
1
pos
A1
S
P
N control
1
1
0
0
-
0
S
P
Free-wheeling
1
1
1
0
-
0
S
P
Free-wheeling
1
1
0
1
-
0
S
P
Stop
Stopping
1
1
1
1
-
0
S
P
Stop
Stopping
NOTe
IN 2 = 0; brake closed
IN 2 = 1; brake open
Stop control =
If KP_H > 0; brake and stop in the current position on changeover to IN A = IN B = 1 + Coasting rh, lh.
If KP_H = 0; brake and stop on changeover to IN A = IN B = 1, run speed to 0.
S = Static
P = Parameter
F = Freeze
D = Dynamic
x = Arbitrary value