beautypg.com

10 parameter description – ebm-papst ECI-63.XX-K4 User Manual

Page 104

background image

104

10 Parameter Description

Parameter 0x44 Parameter 0x45: Distance

Description: Relative distance with sign (+/-). Positive distances are travelled in a clockwise direction.

Parameter 0x46 Parameter 0x47: Positive Positioning window

Description: Position digits, which describe the upper end of the positioning window. This value is added to the target position.

Parameter 0x48 Parameter 0x49: Negative Positioning window

Description: Position digits, which describe the lower end of the positioning window. This value is added to the target position.

Parameter 0x4A: U

ZK

overvoltage threshold

Description: U

ZK

voltage threshold, which is used for monitoring.

Parameter 0x4B: U

ZK

undervoltage threshold

Description: U

ZK

voltage threshold, which is used for monitoring.

Parameter 0x4C: U

ZK

voltage hysteresis

Description: U

ZK

voltage threshold hysteresis, which is used for monitoring. This hysteresis is understood to be an absolute delta.

Parameter 0x4D: Ballast chopper switch on threshold

Description: The switch on threshold specifies a U

ZK

voltage value, at which, when exceeded, the ballast output becomes active. The control of the ballast

resistor lowers the U

ZK

once again.

Parameter 0x4E: Ballast chopper switch off threshold

Description: The switch off threshold specifies a U

ZK

voltage value, at which, when undershot, the ballast output becomes inactive. The control of the ballast

resistor, which lowered the U

ZK

voltage, is switched off.

This manual is related to the following products: