10 parameter description – ebm-papst ECI-63.XX-K4 User Manual
Page 104

104
10 Parameter Description
Parameter 0x44 Parameter 0x45: Distance
Description: Relative distance with sign (+/-). Positive distances are travelled in a clockwise direction.
Parameter 0x46 Parameter 0x47: Positive Positioning window
Description: Position digits, which describe the upper end of the positioning window. This value is added to the target position.
Parameter 0x48 Parameter 0x49: Negative Positioning window
Description: Position digits, which describe the lower end of the positioning window. This value is added to the target position.
Parameter 0x4A: U
ZK
overvoltage threshold
Description: U
ZK
voltage threshold, which is used for monitoring.
Parameter 0x4B: U
ZK
undervoltage threshold
Description: U
ZK
voltage threshold, which is used for monitoring.
Parameter 0x4C: U
ZK
voltage hysteresis
Description: U
ZK
voltage threshold hysteresis, which is used for monitoring. This hysteresis is understood to be an absolute delta.
Parameter 0x4D: Ballast chopper switch on threshold
Description: The switch on threshold specifies a U
ZK
voltage value, at which, when exceeded, the ballast output becomes active. The control of the ballast
resistor lowers the U
ZK
once again.
Parameter 0x4E: Ballast chopper switch off threshold
Description: The switch off threshold specifies a U
ZK
voltage value, at which, when undershot, the ballast output becomes inactive. The control of the ballast
resistor, which lowered the U
ZK
voltage, is switched off.