3 parameterisation, 11 troubleshooting – ebm-papst ECI-63.XX-K4 User Manual
Page 110

110
11 Troubleshooting
11.3 Parameterisation
Command
Feedback
Plain text
Action
Set parameter
Status 0x02
Checksum or telegram length
wrong
Calculate checksum correctly, see
manual
Status 0x10
Access key wrong
Use correct access key
Access to provider parameters with
customer PW
As customer, no possibility of
accessing it
Status 0x20
Parameter conflict
Not an error, information!
But must be corrected.
Notification of conflicting
parameters.
Status 0x28
Telegram can now not be
processed.
Motor active on access to
parameters of the memory class
"appl-func"
Remedy: IN A / IN B = 0 / 0
Read Parameter
Status 0x30
Access key wrong
Use correct access key
Store parameters
Status 0x10
Access key wrong
Use correct access key
Status 0x20
No parameters changed since last
save
Not an error, parameters in the
ROM are up-to-date.
Status 0x80
Data is inconsistent
Remove the conflict between the
parameters
Read status
0x80 0x00
Ready
Everything is ok
0x82 0x00
Ready and active
Everything is ok
0x00 0x00
Calibration run missing
Perform calibration run