beautypg.com

5 validation commands – CANOGA PERKINS 9175 Configuration Guide User Manual

Page 76

background image

CanogaOS Configuration Guide

11-6

DUT# configure terminal

Enter the Configure mode.

DUT (config-if)#exit

Exit the Interface mode

DUT (config)#ethernet cfm enable

Enable CFM globally.

DUT (config)#ethernet cfm cc level 5 vlan 30 interval 10000

Configure the interval in the selected
service instance (MA) instance with the
configured domain-level.

DUT (config)#ethernet cfm cc enable level 5 vlan 30

Enable continuity check in the selected
service instance (MA) instance with the
configured domain-level.

DUT(config-if)# end

Exit the Interface mode.

11.5 Validation Commands

The following command on machine 1 gives the connectivity details of the local machine
DUT1 for the configured domain.

DUT1#show ethernet cfm maintenance-points remote
MPID Level Vlan Remote Mac Age(min) Service ID
------------------------------------------------------------
99 5 30 d427.e2f1.dc09 0 MA10
DUT1#show ethernet cfm maintenance-points local mep
MPID Level Type Vlan Port CC Status Mac Address Domain Name
-------------------------------------------------------------------------
------------------------
66 5 MEP-D 30 eth-0-9 Enabled c23d.d0ed.0309 customer


Linktrace checks

DUT1# linktrace ethernet mep 99 level 5 vlan 30 ttl 64 timeout 5
Sending Ethernet CFM linktrace messages,TTL is 64.Per-Hop Timeout is 10
seconds:
-------------------------------
Received Hops: 1
-------------------------------
TTL : 63
Fowarded : True
Terminal MEP : False
Relay Action : Rly MPDB
Ingress Action : IngOk
Ingress MAC address : 0edb.fe23.8709
Ingress Port ID Type : ifName
Ingress Port ID : eth-0-9

-------------------------------
Received Hops: 2
-------------------------------
TTL : 62
Fowarded : True
Terminal MEP : False
Relay Action : Rly MPDB
Egress Action : EgrOk
Egress MAC address : 1a79.5233.c009
Egress Port ID Type : ifName
Egress Port ID : eth-0-9

-------------------------------
Received Hops: 3