CanogaOS Configuration Guide
11-4
DUT# configure terminal
Enter the Configure mode.
DUT(config-if)# switchport mode trunk
Set the switching characteristics of this
interface to trunk mode.
DUT(config-if)# switchport trunk allowed vlan all
Enable all VLAN IDs on this port.
DUT (config-if)# no shutdown
Bring up the interface.
DUT (config-if)#exit
Exit the Interface mode
DUT (config)#ethernet cfm enable
Enable CFM globally.
DUT (config)#ethernet cfm cc level 3 vlan 30 interval 10000
Configure the interval in the selected
service instance (MA) instance with the
configured domain-level.
DUT (config)#ethernet cfm cc enable level 3 vlan 30
Enable continuity check in the selected
service instance (MA) instance with the
configured domain-level.
DUT(config-if)# end
Exit the Interface mode.
Bridge3
DUT# configure terminal
Enter the Configure mode.
DUT(config)# vlan database
Enter the VLAN database..
DUT(config vlan)# vlan 30
Configure VLAN 30
DUT(config vlan)# exit
Exit the VLAN mode
DUT(config)# ethernet cfm domain customer level 5
Create a domain,
DUT (config-ether-cfm)#service cst vlan 30
Define a Maintenance Association (MA)
for the domain created.
DUT (config-ether-cfm)#exit
Exit the CFM database.
DUT(config)# ethernet cfm domain provider level 3
Create a domain,
DUT (config-ether-cfm)#service cst vlan 30
Define a Maintenance Association (MA)
for the domain created.
DUT (config-ether-cfm)#exit
Exit the CFM database.
DUT(config)#interface eth-0-9
Specify the interface (eth-0-9)to be
configured and enter the Interface mode
DUT(config-if)# switchport mode trunk
Set the switching characteristics of this
interface to trunk mode.
DUT(config-if)# switchport trunk allowed vlan all
Enable all VLAN IDs on this port.
DUT (config-if)# ethernet cfm mip level 5
Configure a maintenance Intermediate
point (MIP).
DUT (config-if)#ethernet cfm mep level 3 up mpid 999 vlan 30
Configure a maintenance end point