Register Map for WebPak 3000 Drives

8-21

N11:77

POSITION

VERNIER

P.241

Output of the position major loop

N11:78

POS

LL

WLO

OUT

P.246

Value of the position loop lead/lag low frequency

N11:79

POS

LL

RATIO

OUT

P.247

Value of the position loop lead/lag ratio

N11:80

POS

PI

KP

OUT

P.248

Value of the position loop PI proportional gain

N11:81

POS

PI

WLD

OUT

P.249

Value of the position loop PI lead frequency

N11:82

POS

LOOP

ERROR

P.254

The difference between

POSITION

REFERENCE

(P.240)

and position feedback

N11:83

TEN

/

DANCER

FDBK

SCALED

P.489

Output of the tension/dancer feedback scaling block

N11:84

TENSION

ON

DIN

TP

P.498

0 =

OFF

, 1 =

ON

N11:85

TENSION

COMMAND

P.850

0 =

OFF

, 1 =

ON

N11:86

STALL

TENSION

COMMAND

P.899

0 =

OFF

, 1 =

ON

N11:87

TEN

TO

CURRENT

OUT

P.876

Output of the tension loop’s tension-to-current scaling
block

N11:88

TEN

PI

KP

OUT

P.879

Value of the tension loop PI proportional gain

N11:89

TENSION

VERNIER

P.856

Output of the tension major loop in counts

N11:90

TAPER

PERCENT

P.859

Percent reduction to be applied to the tension
reference from the taper function

N11:91

TEN

LOOP

ERROR

P.834

Difference between the tension ramp output and the
tension/current loop feedback signal

N11:92

TEN

RAMP

OUTPUT

P.842

Output of the tension major loop ramp block after
tension-to-current conversion

N11:93

TENSION

DEMAND

P.844

Output of the tension setpoint generator in counts

N11:94

ROLL

DIAMETER

P.865

Value of the calculated roll diameter in engineering
units

N11:95

NORM

ROLL

DIAMETER

P.131

Value of the roll diameter normalized at 1.000 at

EMPTY

CORE

DIAMETER

(P.830)

N11:96

DIAMETER

CALC

OUTPUT

P.132

Value of the calculated roll diameter normalized at
1.000 at

EMPTY

CORE

DIAMETER

(P.830)

N11:97

DIAMETER

ANALOG

P.821

Output of the diameter calculator scaled from zero at
empty core to 4095 at full roll diameter

N11:98

DIAMETER

/

TAPER

IN

TP

P.192

Value of the diameter/taper range input in counts after
gain and zero have been applied

N11:99

UNWIND

DIAMETER

IN

P.828

Analog signal of diameter/taper analog input when

DIAMETER

/

TAPER

SELECT

(P.870) is set to diameter.

N11:100

DIAMETER

SELECT

A

TP

P.495

0 =

OFF

, 1 =

ON

N11:101

DIAMETER

SELECT

B

TP

P.496

0 =

OFF

, 1 =

ON

N11:102

DIAMETER

RESET

TP

P.829

0 =

OFF

, 1 =

ON

N11:103

DIAMETER

RST

DIN

TP

P.497

0 =

OFF

, 1 =

ON

N11:104

NETW

COMM

STATUS

P.908

0 =

NOT

ACTIVE

, 1 =

ACTIVE

Table 8.2 – File N11:x (Drive Display Data (Read Only)) for WebPak 3000 Drives (Continued)

File

Address

Parameter Name

Parameter

Number

Description