Rockwell Automation Flex/WebPak 3000 DC Drive ControlNet, Network Communication Board, 915FK2101 User Manual
Page 75
![background image](/manuals/581690/75/background.png)
Register Map for WebPak 3000 Drives
8-7
N10:167
NEG
CURRENT
LIM
SEL
P.224
Config
0 =
REGISTER
1 =
PARALLEL
OCL
2 =
NETW
IN
REG
1
3 =
NETW
IN
REG
2
4 =
NETW
IN
REG
3
N10:168
NEG
CUR
LIM
INV
EN
P.226
Config
0 =
DISABLED
, 1 =
ENABLED
N10:169
INV
FAULT
AVOID
SEL
P.312
Config
0 =
DISABLED
1 =
FAULT
IMMEDIATELY
2 =
DELAY
BEFORE
FAULT
N10:170
FEEDBACK
SELECT
P.200
Config
0 =
ARMATURE
VOLT
1 =
DC
TACH
2 =
ENCODER
N10:171
ANLG
TACH
VOLTS
/1000
P.203
Config
1 = 0.1 volts/1000
RPM
N10:172
ENCODER
PPR
P.207
Config
1 = 1
PPR
N10:173
SPEED
PROFILER
ENABLE
P.127
Config
0 =
DISABLE
, 1 =
ENABLE
N10:174
CURRENT
MEMORY
ENABLE
P.314
Config
0 =
DISABLE
, 1 =
ENABLE
N10:175
EMPTY
CORE
DIAMETER
P.830
Config
1 = 0.01
IN
N10:176
FULL
ROLL
DIAMETER
P.125
Config
1 = 0.01
IN
N10:177
DIAMETER
CALC
ENABLE
P.826
Config
0 =
DISABLE
, 1 =
ENABLE
N10:178
OCL
SELECT
P.817
Config
0 =
NONE
1 =
TENSION
2 =
CURRENT
3 =
POSITION
N10:179
OCL
TYPE
P.818
Config
0 =
CASCADE
, 1 =
PARALLEL
N10:180
OCL
TYPE
3
POSN
REG
EN
P.814
Config
0 =
DISABLED
, 1 =
ENABLED
N10:181
POS
PROFILER
ENABLE
P.253
Config
0 =
DISABLE
, 1 =
ENABLE
N10:182
POS
LEADLAD
BYPASS
P.255
Config
0 =
OFF
, 1 =
ON
N10:183
TAPER
SET
SELECT
P.862
Config
0 =
REGISTER
, 1 =
ANALOG
N10:184
TAPER
TYPE
P.863
Config
0 =
LINEAR
1 =
HYPERBOLIC
2 =
TAPER
REGISTER
N10:185
TEN
PROFILER
ENABLE
P.878
Config
0 =
DISABLE
, 1 =
ENABLE
N10:186
MOTOR
HOT
FLD
AMPS
P.510
Config
1 = 0.01 amps
N10:187
FIELD
REF
SELECT
P.521
Config
0 =
REGISTER
1 =
FULL
FIELD
2 =
FIELD
SHAPING
N10:188
FIELD
DELTA
HIGH
LIM
P.587
Config
1 = 1 degree
N10:189
FIELD
LOSS
THRESHOLD
P.512
Config
1 = 1% of
MOTOR
HOT
FLD
AMPS
N10:190
FIELD
AUTO
WEAKEN
P.517
Config
0 =
DISABLED
, 1 =
ENABLED
N10:191
FULL
FIELD
DIAMETER
P.124
Config
1 = 0.01 in
N10:192
WEAKENED
FIELD
DIA
P.126
Config
1 = 0.01 in
N10:193
MOTOR
SPD
AT
MAX
FLD
P.540
Config
1 = 1
RPM
Table 8.1 – File N10:x (Drive Read/Write Parameters) for WebPak 3000 Drives (Continued)
File
Address
Parameter Name
Parameter
Number
Type
Scale