beautypg.com

Rockwell Automation Flex/WebPak 3000 DC Drive ControlNet, Network Communication Board, 915FK2101 User Manual

Page 88

background image

8-20

ControlNet Network Communication Option Board For Use With FlexPak 3000 and WebPak 3000 DC Drives

N11:51

TENSION

SETPOINT

IN

P.492

Digital value of the tension setpoint input after gain
and zero have been applied

N11:52

TENSION

/

DANCER

FDBK

P.493

Digital value of the tension/dancer feedback input after
gain and zero have been applied

N11:53

DANCER

LOADING

P.820

Rate-limited and scaled value of

TENSION

DEMAND

(P.844)

N11:54

SLACK

TAKE

UP

DIN

TP

P.494

0 =

OFF

, 1 =

ON

N11:55

SLACK

TAKE

UP

COMMAND

P.317

0 =

OFF

, 1 =

ON

N11:56

CURRENT

MEM

DIN

TP

P.499

0 =

OFF

, 1 =

ON

N11:57

CURRENT

MEM

COMMAND

P.319

0 =

OFF

, 1 =

ON

N11:58

FLD

CURRENT

REGULATOR

P.586

0 =

NOT

INSTALLED

1 = 4 amp
2 = 10 amp
3 = 20 amp

N11:59

FIELD

DELTA

P.588

Field firing angle in degrees

N11:60

FIELD

FEEDBACK

(10 ms update)

P.589

Motor field feedback value

N11:61

FIELD

REFERENCE

P.590

Field current reference value

N11:62

NORM

FIELD

REF

P.130

Normalized reference to the field shaping table

N11:63

FIELD

ECONOMY

ACTIVE

P.599

0 =

OFF

, 1 =

ON

N11:64

LEVEL

DETECT

1

OUTPUT

P.648

0 =

OFF

, 1 =

ON

N11:65

LEVEL

DETECT

2

OUTPUT

P.649

0 =

OFF

, 1 =

ON

N11:66

J

11

ANLG

TACH

VLT

SCL

P.792

0 = 16
1 = 31/125
2 = 62/250

N11:67

J

14

ANLG

TACH

VLT

RNG

P.793

0 =

LOW

, 1 =

HIGH

N11:68

REGULATOR

SW

VERSION

P.794

V.VV, Regulator board firmware version number

N11:69

POWER

UNIT

TYPE

P.795

0 = S6R, 1 = S6

N11:70

NETWORK

KIT

P.796

0 =

NOT

INSTALLED

1 =

INSTALLED

2 =

FAILED

DIAGS

N11:71

I

/

O

EXPANSION

KIT

P.797

0 =

NOT

INSTALLED

1 =

INSTALLED

2 =

FAILED

DIAGS

N11:72

ENCODER

KIT

P.798

0 =

NOT

INSTALLED

1 =

INSTALLED

2 =

FAILED

DIAGS

N11:73

J

15

REGULATOR

TYPE

P.799

0 =

SPEED

/

VOLTAGE

, 1 =

CURRENT

/

TORQUE

N11:74

OCL

PARALLEL

OUT

P.816

Output of the selected outer control loop for parallel
mode

N11:75

OCL

OUTPUT

P.848

OCL output value added to

SPEED

RAMP

OUTPUT

(P.199)

N11:76

POS

RAMP

OUTPUT

P.237

Output of the position major loop ramp block

Table 8.2 – File N11:x (Drive Display Data (Read Only)) for WebPak 3000 Drives (Continued)

File

Address

Parameter Name

Parameter

Number

Description