beautypg.com

Rockwell Automation Flex/WebPak 3000 DC Drive ControlNet, Network Communication Board, 915FK2101 User Manual

Page 85

background image

Register Map for WebPak 3000 Drives

8-17

Table 8.2 – File N11:x (Drive Display Data (Read Only)) for WebPak 3000 Drives

File

Address

Parameter Name

Parameter

Number

Description

N11:0

Drive Status Word 1

---

b00 Ready
b01 Running
b02 Fault Active
b03 Jogging Fwd
b04 Jogging Rev
b05 Underwind Active
b06 Stopping
b07 Tension on Active
b08 Stall Tension Active
b09 Current Memory Active
b10 Current Limit
b11 Alarm Active
b12 Current/Speed Active
b13 Processing Error
b14 Level Detect 1 Output
b15 Level Detect 2 Output

N11:1

Drive Status Word 2

---

b00 FN/DB Status (0 = open, 1 = closed)
b01 TB Customer Interlock (0 = open, 1 = closed)
b02 TB Section Run
b03 TB Jog Rev
b04 TB Jog Fwd
b05 TB Section Off
b06 TB Coast/DB Interlock
b07 TB Fault Reset
b08 TB Diameter Sel A
b09 TB Diameter Sel B
b10 TB Diameter Reset
b11 TB Tension On
b12 TB Current Memory
b13 TB Underwind
b14 TB Slack Take Up
b15 Reserved

N11:2

SPD

LOOP

REFERENCE

P.295

Final speed loop reference value before the speed
regulator

N11:3

SPD

LOOP

FEEDBACK

P.296

Speed loop feedback value, after all conditioning and
scaling

N11:4

SPD

LOOP

OUTPUT

P.299

Speed loop PI output value

N11:5

ARMATURE

VOLTAGE

P.289

Armature voltage value after scaling, before IR
compensation

N11:6

Average CML Feedback

---

Current Minor Loop feedback average over last 8 CML
scans

N11:7

Network Output Reg 1

---

Value of parameter from

NETW

OUT

REG

1

SELECT

(P.902)

N11:8

Network Output Reg 2

---

Value of parameter from

NETW

OUT

REG

2

SELECT

(P.903)