Rockwell Automation Flex/WebPak 3000 DC Drive ControlNet, Network Communication Board, 915FK2101 User Manual
Page 55
Register Map for FlexPak 3000 Drives
7-3
N10:57
TRIM
REFERENCE
SELECT
P.108
Tunable
0 =
REGISTER
1 =
ANALOG
MANUAL
2 =
ANALOG
IN
1
3 =
NETW
IN
REG
1
4 =
NETW
IN
REG
2
5 =
NETW
IN
REG
3
6 =
ANALOG
IN
2
N10:58
TRIM
RANGE
P.109
Tunable
1 = 0.1%
N10:59
TRIM
MODE
SELECT
P.110
Tunable
0 =
NO
TRIM
1 =
INCREMENTAL
2 =
PROPORTIONAL
N10:60
MOP
ACCEL
TIME
P.115
Tunable
1 = 0.1 s
N10:61
MOP
DECEL
TIME
P.120
Tunable
1 = 0.1 s
N10:62
PRESET
SPEED
1
P.117
Tunable
1 = 1
RPM
N10:63
PRESET
SPEED
2
P.118
Tunable
1 = 1
RPM
N10:64
PRESET
SPEED
3
P.119
Tunable
1 = 1
RPM
N10:65
ANALOG
TACH
GAIN
ADJ
P.201
Tunable
1 = 0.001
N10:66
ANALOG
TACH
ZERO
ADJ
P.202
Tunable
N10:67
ARM
VOLTAGE
GAIN
ADJ
P.204
Tunable
1 = 0.001
N10:68
ARM
VOLTAGE
ZERO
ADJ
P.205
Tunable
N10:69
ANLG
AUTO
GAIN
ADJ
P.101
Tunable
1 = 0.001
N10:70
ANLG
AUTO
ZERO
ADJ
P.102
Tunable
N10:71
ANLG
MAN
REF
GAIN
ADJ
P.104
Tunable
1 = 0.001
N10:72
ANLG
MAN
REF
ZERO
ADJ
P.105
Tunable
N10:73
ANLG
IN
1
GAIN
ADJ
P.415
Tunable
1 = 0.001
N10:74
ANLG
IN
1
ZERO
ADJ
P.414
Tunable
N10:75
ANLG
IN
2
GAIN
ADJ
P.417
Tunable
1= 0.001
N10:76
ANLG
IN
2
ZERO
ADJ
P.416
Tunable
N10:77
METER
OUT
1
GAIN
ADJ
P.400
Tunable
1= 0.001
N10:78
METER
OUT
1
ZERO
ADJ
P.402
Tunable
Table 7.1 – File N10:x (Drive Read/Write Parameters) for FlexPak 3000 Drives (Continued)
File
Address
Parameter Name
Parameter
Number
Type
Scale