Hapter, Register map for flexpak 3000 drives – Rockwell Automation Flex/WebPak 3000 DC Drive ControlNet, Network Communication Board, 915FK2101 User Manual
Page 53

Register Map for FlexPak 3000 Drives
7-1
C
HAPTER
7
Register Map for
FlexPak 3000 Drives
Table 7.1 – File N10:x (Drive Read/Write Parameters) for FlexPak 3000 Drives
File
Address
Parameter Name
Parameter
Number
Type
Scale
N10:0
Reserved
---
Tunable
Reserved
N10:1
ACCELERATION
TIME
P.001
Tunable
1 = 0.1 s
N10:2
DECELERATION
TIME
P.002
Tunable
1 = 0.1 s
N10:3
MINIMUM
SPEED
P.003
Tunable
1 = 1
RPM
N10:4
MAXIMUM
SPEED
P.004
Tunable
1 = 1
RPM
N10:5
POSITIVE
CURRENT
LIM
P.005
Tunable
1 = 1% of
MOTOR
RATED
ARM
AMPS
(P.008)
N10:6
NEGATIVE
CURRENT
LIM
P.006
Tunable
1 = 1% of
MOTOR
RATED
ARM
AMPS
(P.008)
N10:7
S
-
CURVE
ROUNDING
P.014
Tunable
1 = 1%
N10:8
IR
COMPENSATION
P.206
Tunable
1 = 1%
N10:9
CURRENT
COMPOUNDING
P.209
Tunable
1 = 1%
N10:10
AUTO
MODE
MIN
BYPASS
P.111
Tunable
0 =
OFF
, 1 =
ON
N10:11
AUTO
MODE
RAMP
BYPASS
P.112
Tunable
0 =
OFF
, 1 =
ON
N10:12
NORMALIZED
INERTIA
P.222
Tunable
1 = 0.01 s
N10:13
CML
PI
PROP
GAIN
P.301
Tunable
1 = 0.001
N10:14
CML
PI
LEAD
FREQUENCY
P.302
Tunable
1 = 1 rad/s
N10:15
CML
REF
RATE
LIMIT
P.303
Tunable
1 = 1 ms
N10:16
SPD
LOOP
PI
PROP
GAIN
P.211
Tunable
1 = 0.01
N10:17
SPD
LOOP
PI
LEAD
FREQ
P.212
Tunable
1 = 0.01 rad/s
N10:18
SPD
LEADLAG
RATIO
P.213
Tunable
N10:19
SPD
LEADLAG
LOW
FREQ
P.214
Tunable
1 = 0.01 rad/s
N10:20
SPD
LOOP
LAG
FREQ
P.215
Tunable
1 = 0.01 rad/s
N10:21
SPD
LEADLAG
SELECT
P.216
Tunable
0 =
LEAD
/
LAG
1 =
BYPASS
2 =
LAG
/
LEAD
N10:22
SPD
LOOP
LAG
BYPASS
P.217
Tunable
0 =
OFF
, 1 =
ON
N10:23
CML
FEEDBACK
GAIN
ADJ
P.300
Tunable
1 = 0.001
N10:24
OCL
LEADLAG
SELECT
P.805
Tunable
0 =
LEAD
/
LAG
1 =
BYPASS
2 =
LAG
/
LEAD
N10:25
OCL
LEADLAG
LOW
FREQ
P.806
Tunable
1 = 0.01 rad/s
N10:26
OCL
LEADLAG
RATIO
P.807
Tunable