beautypg.com

Sl0 logic step, Step logic – Rockwell Automation 1336Z SPIDER - FRN 2.xxx-5.xxx User Manual

Page 133

background image

Programming

7–61

Figure 7.1
Step Logic

Step Logic

0

1

3

4

5

6

End

10 Sec

60Hz

50Hz

40Hz

30Hz

20Hz

10Hz

0Hz

-10Hz

-20Hz

-30Hz

-40Hz

-50Hz

SL Input 1

SL Input 2

Step Logic Output

-15

10

5
0

-5

-10

15

0

20
15
10

5

Start

Encoder Counts

Since Start

of Step

Pulse Counts

Since Start

of Step

[SL0 Logic Step]

– Firmware 5.001 & later

[SL1 Logic Step]
[SL2 Logic Step]
[SL3 Logic Step]
[SL4 Logic Step]
[SL5 Logic Step]
[SL6 Logic Step]

When the logic in this parameter is true, the program will
move to the next step. The SL1 and SL2 inputs are desig-
nated in [TB3 Term xx Sel].

The logic which refers to time is also for encoder or pulse
counts. Time can be replaced with counts when using the
encoder and pulse inputs.

When using “Time and SLx” or “Time not SLx” the time or
counts need to elapse before the logic input will be
checked.

Parameter Number 335, 341, 347, 353, 359, 365, 371
Parameter Type

Read and Write

Factory Default

“Step On Time”

Units

Display Drive

“Skip Step” 0

“Step On Time” 1

“SL1 In True” 2
“SL2 In True” 3

“SL1 In False” 4
“SL2 In False” 5

“Any SL True” 6

“All SL True” 7

“No SL True” 8

“SL1 not SL2” 9
“SL2 not SL1” 10

“Time and SL1” 11
“Time and SL2” 12

“Time not SL1” 13
“Time not SL2” 14

“Do Not Step” 15