Bulletin 280E/281E/284E Programmable Parameters Chapter 7
Linear List of Parameters
for Bulletin 280E/281E and
Bulletin 284E
Table 28 - ArmorStart Common Parameters
Parameter
Number
Parameter Name
Description
Factory Default
Group
Controller
1
Hdw Inputs
This parameter provides status of hardware inputs.
0
Basic Status
Common
2
Network Inputs
This parameter provides status of network inputs.
0
Basic Status
Common
3
Network Outputs
This parameter provides status of network outputs.
0
Basic Status
Common
4
Trip Status
This parameter provides trip identification.
0
Basic Status
Common
5
Starter Status
This parameter provides the status of the starter.
0
Basic Status
Common
6
InternalLinkStat
Status of the internal network connections.
0
Basic Status
Common
7
Starter Command
The parameter provides the status of the starter
command.
0
Basic Status
Common
8
Network Override
This parameter allows for the local logic to override a
Network fault.
0
Misc. Configuration
Common
9
Comm Override
This parameter allows for local logic to override a
absence of an I/O connection.
0
Misc. Configuration
Common
10
Reserved
— —
Network Configuration
Common
11
Reserved
—
—
Network Configuration
Common
12
Reserved
—
—
Network Configuration
Common
13
Prod Assy Word 0
This parameter is used to build bytes 0…1 for
produced assembly 150 or 151.
0
Network Configuration
Common
14
Prod Assy Word 1
This parameter is used to build bytes 2…3 for
produced assembly 150 or 151.
0
Network Configuration
Common
15
Prod Assy Word 2
This parameter is used to build bytes 4…5 for
produced assembly 150 or 151.
0
Network Configuration
Common
16
Prod Assy Word 3
This parameter is used to build bytes 6…7 for
produced assembly 150 or 151.
0
Network Configuration
Common
17
Reserved
— —
Basic Status
Common
18
Reserved
—
—
Basic Status
Common
19
Reserved
—
—
Network Configuration
Common
20
Reserved
—
—
Network Configuration
Common
21
Reserved
—
—
Network Configuration
Common
22
Breaker Type
This parameter identifies the Bulletin 140M used in this
product.
0 =
140M-D8N-C10
Basic Status
Common
23
Pr FltReset Mode
This parameter configures the Protection Fault reset
mode.
0 = Manual
Starter Protection
Common
24
Pr Fault Enable
This parameter enables the Protection Fault by setting
the bit to 1.
12419
Starter Protection
Common
25
Pr Fault Reset
This parameter resets the Protection Fault on a
transition 0 > 1.
0
Starter Protection
Common