I/o wiring examples, 24 installation/wiring – Rockwell Automation 22C PowerFlex 400 AC Drive FRN 1.xx - 7.xx User Manual
Page 36

1-24
Installation/Wiring
PowerFlex 400 Adjustable Frequency AC Drive FRN 1.xx - 7.xx User Manual
Publication 22C-UM001I-EN-P
I/O Wiring Examples
Input/Output
Connection Example
Required Settings
Potentiometer
1-10k Ohm Potentiometer
Recommended
(2 Watt Minimum)
DIP Switch
AI1 = 10V
Parameters
P038 [Speed Reference] = 2 “Analog In1”
T069 [Analog In 1 Sel] = 2 “0-10V”
Scaling
T070 [Analog In 1 Lo]
T071 [Analog In 1 Hi]
Check Results
d305 [Analog In 1]
Analog Input
Bipolar Speed Reference,
±10V Input
DIP Switch
AI2 = 10V
Parameters
P038 [Speed Reference] = 3 “Analog In2”
T073 [Analog In 2 Sel] = 3 “-10 to +10V”
Scaling
T074 [Analog In 2 Lo]
T075 [Analog In 2 Hi]
Check Results
d306 [Analog In 2]
Analog Input
Unipolar Speed Reference,
0 to +10V Input
DIP Switch
AI1 = 10V
Parameters
P038 [Speed Reference] = 2 “Analog In1”
T069 [Analog In 1 Sel] = 2 “0-10V”
Scaling
T070 [Analog In 1 Lo]
T071 [Analog In 1 Hi]
Check Results
d305 [Analog In 1]
Analog Input
Unipolar Speed Reference,
4-20 mA Input
DIP Switch
AI1 = 20MA
Parameters
P038 [Speed Reference] = 2 “Analog In1”
T069 [Analog In 1 Sel] = 1 “4-20 mA”
Scaling
T070 [Analog In 1 Lo]
T071 [Analog In 1 Hi]
Check Results
d305 [Analog In 1]
Analog Output
Unipolar, 0 to +10V Output
•
1k Ohm Minimum
DIP Switch
AO1 = 10V
Parameters
T082 [Analog Out1 Sel] = 0 through 6
Scaling
T083 [Analog Out1 High]
T084 [Analog Out1 Setpt]
12
13
14
17
18
-/+ 10V
Common
13
14
+
Common
13
14
+
Common
14
15
Common
+