A174, A175, A176 – Rockwell Automation 22C PowerFlex 400 AC Drive FRN 1.xx - 7.xx User Manual
Page 103: A177, Dc br, Advanced program group (continued), A174 [maximum voltage, A175 [slip hertz @ fla, A176 [dc brake time, A177 [dc brake level

Programming and Parameters
3-45
PowerFlex 400 Adjustable Frequency AC Drive FRN 1.xx - 7.xx User Manual
Publication 22C-UM001I-EN-P
Advanced Program Group (continued)
A174 [Maximum Voltage]
,
Sets the highest voltage the drive will output.
Values
Default:
Drive Rated Volts
Min/Max:
20/Drive Rated Volts
Display:
1 VAC
A175 [Slip Hertz @ FLA]
Related Parameter(s):
Compensates for the inherent slip in an induction motor. This frequency is added to the commanded
output frequency based on motor current.
Values
Default:
2.0 Hz
Min/Max:
0.0/10.0 Hz
Display:
0.1 Hz
A176 [DC Brake Time]
Related Parameter(s):
,
Sets the length of time that DC brake current is “injected” into the motor when
to either 4 “Ramp” or 6 “DC Brake”. Refer to parameter
[DC Brake Level].
Values
Default:
0.0 Secs
Min/Max:
0.0/99.9 Secs (A setting of 99.9 = Continuous)
Display:
0.1 Secs
A177 [DC Brake Level]
Related Parameter(s):
,
Defines the maximum DC brake current, in amps, applied to the motor.
Values
Default:
Drive Rated Amps
×
0.05
Min/Max:
0.0/(Drive Rated Amps
×
1.5)
Display:
0.1 Amps
DC Injection Braking Mode
V
olts/S
p
eed
Voltage
Time
Stop Command
Speed
[DC Brake Level]
[DC Brake Time]
V
olts/S
p
eed
Ramp-to-Stop Mode
Time
Stop Command
[DC Brake Level]
[DC Brake Time]
Voltage
Speed
ATTENTION:
If a hazard of injury due to movement of equipment or material exists,
an auxiliary mechanical braking device must be used.
ATTENTION:
This feature should not be used with synchronous or permanent
magnet motors. Motors may be demagnetized during braking.