D315, D317, D316 – Rockwell Automation 22C PowerFlex 400 AC Drive FRN 1.xx - 7.xx User Manual
Page 121: Advanced display group (continued)

Programming and Parameters
3-63
PowerFlex 400 Adjustable Frequency AC Drive FRN 1.xx - 7.xx User Manual
Publication 22C-UM001I-EN-P
Advanced Display Group (continued)
d312 [Fault 2 Time-hr]
,
Displays the value of the
[Elapsed Time-hr] parameter when the fault occurred.
Values
Default:
Read Only
Min/Max:
0/32767 Hr
Display:
1 Hr
d313 [Fault 2 Time-min]
,
Displays the value of the
[Elapsed Time-min] parameter when the fault occurred.
Values
Default:
Read Only
Min/Max:
0.0/60.0 Min
Display:
0.1 Min
d314 [Fault 3 Time-hr]
,
Displays the value of the
[Elapsed Time-hr] parameter when the fault occurred.
Values
Default:
Read Only
Min/Max:
0/32767 Hr
Display:
1 Hr
d315 [Fault 3 Time-min]
,
Displays the value of the
[Elapsed Time-min] parameter when the fault occurred.
Values
Default:
Read Only
Min/Max:
0.0/60.0 Min
Display:
0.1 Min
d316 [Elapsed Time-hr]
,
Displays the total elapsed powered-up time (in hours) since timer reset. The timer stops when it
reaches maximum.
Values
Default:
Read Only
Min/Max:
0/32767 Hr
Display:
1 Hr
d317 [Elapsed Time-min]
,
Displays the total elapsed powered-up time (in minutes) since timer reset. The timer will increment the
hour parameter when appropriate.
Values
Default:
Read Only
Min/Max:
0.0/60.0 Min
Display:
0.1 Min