Working with the sample projects
Sample project with the "Actuator speed" application - Actuator Speed
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.1.5
Program structure in the »PLC Designer«
How to proceed:
1. Open the desired sample project (CAN or EtherCAT) in the »PLC Designer«.
2. Load the project to the Controller and Go online.
7.1.5.1
Control configuration
CAN
• The CAN master (ID = 127) is the control section of the system configuration
• The controller (CAN node ID = 5) is attached below the CAN master.
• Below the controller, the axis data are available in the form of an additional node.
• One PDO for CAN-Input and one PDO for CAN-Output is used, respectively.
• The transmission mode is sync-controlled (10 ms)
You can find further details on the extension of the control configuration with CAN and EtherCAT in
the following section:
Extending sample projects - adding devices
EtherCAT
• The EtherCAT master is the control section of the system configuration
• The controller (station ID = 1001) is attached below the EtherCAT master.
• Below the controller, the axis data are available in the form of an additional node.