14 l_lcb_speed_ntonorm_r - signal converter, 15 l_lcb_speed_rtonorm_n - signal converter, L_lcb_speed_ntonorm_r - signal converter ( 134) – Lenze PLC Designer R3-x User Manual
Page 134: L_lcb_speed_rtonorm_n - signal converter ( 134), The l_lcb_logiccontrolbasic library
The L_LCB_LogicControlBasic library
L_LCB_Speed_nToNorm_r - signal converter
134
Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.14
L_LCB_Speed_nToNorm_r - signal converter
This function converts a 32 bit input signal into a 32 bit percentage signal.
Input
Output signal
L_LCB_Speed_nToNorm_r REAL 0- 100.0 %
13.15
L_LCB_Speed_rToNorm_n - signal converter
This function converts the input signal transferred to a 32 bit signal of the REAL data type.
Input
Output signal
L_LCB_Speed_rToNorm_n 0 -2
30
= 1073741824
Function library:
L_LCB_LogicControlBasic
Runtime software licence:
LPC 1x00
MPC 1x00
MPC 2xx0
MPC 3x00
L_LCB_Speed_nToNorm_r
DINT ⎯ diIn_n
L_LCB_Speed_nToNorm_r ⎯
Identifier/data type
Information/possible settings
diIn_n
DINT
Input signal in [%] 100 % ≡ 2
30
= 1073741824
Function library:
L_LCB_LogicControlBasic
Runtime software licence:
LPC 1x00
MPC 1x00
MPC 2xx0
MPC 3x00
L_LCB_Speed_rToNorm_n
REAL ⎯ rIn_r
L_LCB_Speed_rToNorm_n ⎯
Identifier/data type
Information/possible settings
rIn_r
REAL
Input signal 0-100.0 %