21 l_lcb_getposition - conversion block, L_lcb_getposition - conversion block ( 139), The l_lcb_logiccontrolbasic library – Lenze PLC Designer R3-x User Manual
Page 139

Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014
139
The L_LCB_LogicControlBasic library
L_LCB_GetPosition - conversion block
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.21
L_LCB_GetPosition - conversion block
This FB converts the input signal transmitted to a position signal.
Inputs
Outputs
Function library:
L_LCB_LogicControlBasic
Runtime software licence:
LPC 1x00
MPC 1x00
MPC 2xx0
MPC 3x00
L_LCB_GetPosition
DINT ⎯ diPosIn_p
rPositionOutUnits ⎯ REAL
⎯ scAxisData
xError ⎯ BOOL
eError ⎯
Identifier/data type
Information/possible settings
diPosIn_p
DINT
Position in [increments]
Scaling: 1 encoder revolution ≡ 2
16
increments (or according to scAxisData)
scAxisData
Machine parameters
Identifier/data type
Information/possible settings
rPositionOutUnits
REAL
Position value
Display of the input signal dnPosIn_p in the real unit of the machine.
xError
BOOL
"Error" status signal at the function block
FALSE Conversion carried out without errors
TRUE Error during the conversion
eError
Error number, error code