L_LCB_Norm_nToSpeed_s - signal converter
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.13.1
LCB_Axis_logic
Function library:
L_LCB_LogicControlBasic
Runtime software licence:
LPC 1x00
MPC 1x00
MPC 2xx0
MPC 3x00
Identifier/data type
Information/possible settings
dwAxisID
DWORD
Axis assignment
rFeedConstant
REAL
Feed constant
rInvFeedConstant
REAL
Inverse feed constant
rCycleLength
REAL
Cycle length (only Modulo operation)
dwGearNumerator
DWORD
Gearbox factor (numerator)
dwGearDenominator
Gearbox factor (denominator)
rMaxSpeed
REAL
Maximum speed
diReferenceSpeed_s
DINT
Reference speed
sAxisName
STRING
Axis name
eMode
SSC_Mode
Operating mode
0 Modulo
1 Limited
2 Unlimited
dwResolution
DWORD
Encoder resolution
rEncoderGear
REAL
Resolution of one encoder revolution
rInvEncoderGear
REAL
Inverted resolution of one encoder revolution
diCycleLength_p
DINT
Cycle
rUnitsToPos
REAL
Internal calculation value
rPosToUnits
REAL
Internal calculation value
rUnitsToSpeed
REAL
Internal calculation value
rSpeedToUnits
REAL
Internal calculation value
rTimeUnit
REAL
Internal calculation value
xValid
BOOL
FALSE: Invalid axis data structure