26 l_lcb_acctounit - acceleration value conversion, The l_lcb_logiccontrolbasic library – Lenze PLC Designer R3-x User Manual
Page 144
The L_LCB_LogicControlBasic library
L_LCB_AccToUnit - acceleration value conversion
144
Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.26
L_LCB_AccToUnit - acceleration value conversion
This FB converts an acceleration value specified in the internal unit [rpm/s] to an acceleration value
in the real unit of the machine on the basis of the machine parameters transmitted.
Inputs
Outputs
Function library:
L_LCB_LogicControlBasic
Runtime software licence:
LPC 1x00
MPC 1x00
MPC 2xx0
MPC 3x00
L_LCB_AccToUnit
DINT ⎯ diAccIn_x
diAccOut_e4 ⎯ DINT
⎯ scAxisData
xLimit ⎯ BOOL
xError ⎯ BOOL
eError ⎯
Identifier/data type
Information/possible settings
diAccIn_x
DINT
Acceleration as speed variation/time
in [rpm/s] 15000 rpm/s ≡ 2
22
= 4194304
scAxisData
Machine parameters
Identifier/data type
Information/possible settings
diAccOut_e4
DINT
Acceleration in unit/s
2
]
• Display in "e4" view (fixed point with four decimal positions)
xLimit
BOOL
"Output signal is limited" status
• TRUE: The output signal is limited to the representable value range
±214748.3647
xError
BOOL
"Error" status signal
FALSE Conversion carried out without errors
TRUE Error during the conversion
eError
Error number, error code